Literature DB >> 11814224

Updating of form factor tabulations for coherent scattering of photons in tissues.

A Tartari1, A Taibi, C Bonifazz, C Baraldi.   

Abstract

An updating of photon transport modelling in tissues is carried out by including the effect of molecular interference in the coherent (Rayleigh) scattering. To this end, the present tabulations--which permit us to obtain the linear differential scattering coefficient of compounds from a simple weighted sum of the elemental components--are integrated by adding files for a limited set of molecular interference functions. This set originates from a four-component model which is found to be capable of reproducing human tissues in situations involving bony and soft tissues. The proposed procedure overcomes, in the computation, the hindrance that the dependence on molecular interference effects leads every tissue to have its own diffraction pattern, which is not easily obtained by means of measurements or calculations.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11814224     DOI: 10.1088/0031-9155/47/1/312

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

2.  Monte Carlo simulation of coherently scattered photons based on the inverse-sampling technique.

Authors:  Wazir Muhammad; Ying Liang; Gregory R Hart; Bradley J Nartowt; Jun Deng
Journal:  Acta Crystallogr A Found Adv       Date:  2020-01-01       Impact factor: 2.290

3.  Small-angle X-ray scattering characteristics of mouse brain: Planar imaging measurements and tomographic imaging simulations.

Authors:  Mina Choi; Bahaa Ghammraoui; Aldo Badano
Journal:  PLoS One       Date:  2017-10-31       Impact factor: 3.240

4.  Source of statistical noises in the Monte Carlo sampling techniques for coherently scattered photons.

Authors:  Wazir Muhammad; Sang Hoon Lee
Journal:  J Radiat Res       Date:  2012-09-14       Impact factor: 2.724

5.  Identification of amyloid plaques in the brain using an x-ray photon-counting strip detector.

Authors:  Bahaa Ghammraoui; Aldo Badano
Journal:  PLoS One       Date:  2020-02-11       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.