Literature DB >> 11813664

Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysis.

K Akça1, H Iplikçioğlu.   

Abstract

Buccolingual angulation of the mandibular posterior edentulous region may affect the prosthetic load conditions, so as to cause high stress concentrated areas that may easily lead to failure. The aim of this study was to evaluate the effect of various predetermined buccolingual angulation values on stress distribution in the mandibular posterior edentulous region restored with implant-supported fixed partial dentures, using three-dimensional finite element analysis. Stress analyses were performed applying 400N oblique force to implant-supported fixed prosthesis. Stress analyses indicated tensile stress values on the buccal surface and compressive stress values on the lingual surface of cortical bone were increased as the angulation of the edentulous bone increased (especially corresponding to the cervical region of the implants). Compressive stress values, observed where two implants were placed at the second premolar and second molar regions (5-7 design) and first and second molar regions (6-7 design), respectively, were very close to or even exceeded the ultimate compressive strength of bone. It is concluded that when a definite buccolingual angulation is added to other existing risk factors such as bruxism, placing an implant for every missing tooth might reduce the high stress concentration areas.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11813664     DOI: 10.1097/00008505-200110000-00006

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  5 in total

1.  Relationship between CBCT and panoramic images of the morphology and angulation of the posterior mandibular jaw bone.

Authors:  Mehmet Ertuğrul Çiftçi; Ali Murat Aktan; Özlem İşman; Eren Yıldırım
Journal:  Surg Radiol Anat       Date:  2015-09-14       Impact factor: 1.246

2.  Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area.

Authors:  Ting-Hsun Lan; Je-Kang Du; Chin-Yun Pan; Huey-Er Lee; Wei-Hao Chung
Journal:  Clin Oral Investig       Date:  2011-02-08       Impact factor: 3.573

3.  The Biomechanical Effect of Different Denture Base Materials on the Articular Disc in Complete Denture Wearers: A Finite Element Analysis.

Authors:  Mohamed M El-Zawahry; Ahmed A El-Ragi; Mohamed I El-Anwar; Eman M Ibraheem
Journal:  Open Access Maced J Med Sci       Date:  2015-07-13

4.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11

5.  Effects of crown retrieval on implants and the surrounding bone: a finite element analysis.

Authors:  Serhat Emre Ozkir; Server Mutluay Unal; Emel Yurekli; Sedat Güven
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

  5 in total