Literature DB >> 11801966

Methylene blue and sestamibi: complementary tools for localizing parathyroids.

L A Orloff1.   

Abstract

OBJECTIVE: To determine the value and correlation between sestamibi scan and methylene blue staining for localization of parathyroid glands in patients with primary hyperparathyroidism. STUDY
DESIGN: Nonrandomized convenience sample, followed prospectively.
METHODS: Twenty-three consecutive patients underwent 24 operations for primary hyperparathyroidism. All patients underwent preoperative technetium 99m-sestamibi planar scintigraphy, preoperative administration of 7.5 mg/kg methylene blue initiated within 60 minutes of surgical incision, and surgical neck exploration supervised by a single surgeon.
RESULTS: All patients were cured of hypercalcemia. Sensitivity for sestamibi and for methylene blue staining was 76% and 79%, respectively. Specificity for sestamibi and for methylene blue was 98% and 93%, respectively. Agreement between sestamibi and methylene blue was 96%.
CONCLUSIONS: Sestamibi scanning and methylene blue staining are useful, complementary localizing tools for patients undergoing surgery for primary hyperparathyroidism. When used together, these studies decrease operative time, justify unilateral exploration in patients with parathyroid adenoma, and increase the ease of identification of hyperplastic parathyroid glands.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11801966     DOI: 10.1097/00005537-200111000-00005

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  7 in total

1.  Fluorescence-guided minimally invasive parathyroidectomy: a novel detection technique for parathyroid glands.

Authors:  R L Prosst; F Willeke; L Schroeter; S Post; J Gahlen
Journal:  Surg Endosc       Date:  2006-05-26       Impact factor: 4.584

2.  Fluorescence-guided minimally invasive parathyroidectomy: clinical experience with a novel intraoperative detection technique for parathyroid glands.

Authors:  Ruediger L Prosst; Johannes Weiss; Linus Hupp; Frank Willeke; Stefan Post
Journal:  World J Surg       Date:  2010-09       Impact factor: 3.352

3.  Intraoperative guidance in parathyroid surgery using near-infrared fluorescence imaging and low-dose Methylene Blue.

Authors:  Quirijn R J G Tummers; Abbey Schepers; Jaap F Hamming; J Kievit; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  Surgery       Date:  2015-05-06       Impact factor: 3.982

Review 4.  Intraoperative adjuncts in surgery for primary hyperparathyroidism.

Authors:  Barney J Harrison; Frederic Triponez
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

5.  Intraoperative near-infrared fluorescence imaging of parathyroid adenomas with use of low-dose methylene blue.

Authors:  Joost R van der Vorst; Boudewijn E Schaafsma; Floris P R Verbeek; Rutger-Jan Swijnenburg; Quirijn R J G Tummers; Merlijn Hutteman; Jaap F Hamming; Job Kievit; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  Head Neck       Date:  2013-10-04       Impact factor: 3.147

Review 6.  Combination of Fluorescence-Guided Surgery With Photodynamic Therapy for the Treatment of Cancer.

Authors:  Jun He; Leping Yang; Wenjun Yi; Wentao Fan; Yu Wen; Xiongying Miao; Li Xiong
Journal:  Mol Imaging       Date:  2017 Jan-Dec       Impact factor: 4.488

7.  Effectiveness of the Gamma Probe in Childhood Parathyroidectomy: Retrospective Study.

Authors:  Ozgur Caglar; Ibrahim Otgun; Hatice Yalcin Comert; Arzu Gencoglu; Esra Baskin
Journal:  Cureus       Date:  2020-01-11
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.