Literature DB >> 11792592

Accuracy and precision of bone mineral density and bone mineral content in excised rat humeri using fan beam dual-energy X-ray absorptiometry.

S Kastl1, T Sommer, P Klein, W Hohenberger, K Engelke.   

Abstract

The aim of this study was the evaluation of fan beam dual-energy X-ray absorptiometry (DXA) for measuring bone mineral density (BMD) and bone mineral content (BMC) of isolated rat humeri. Defleshed rat humeri from male Lewis rats were examined with a Hologic QDR 4500 A (Hologic, Inc., Bedford, MA) high-resolution densitometer both in water and 0.9% saline solution. The small animal scan protocol with the regional high-resolution mode was used. BMC measured by DXA was compared with bone dry weight, ash weight, and bone calcium content. Furthermore, DXA BMD and BMC precision were determined. We also evaluated the effect of salinity of the water bath in which the bones were measured. Correlations (r(2)) of BMC, as determined by DXA with dry weight, ash weight, and bone calcium content, were 0.978, 0.988, and 0.890, respectively. DXA overestimated ash weight by 5%-9%. Precision errors for BMC (BMD) were 0.90% (0.76%) without and 1.3 (0.86) with repositioning. Changes in the salinity of the water bath had a significant influence on the DXA results: At the 0.9% physiological level, BMC (-4.4%) and area (-4.1%), but not BMD, values were significantly lower (p < 0.005) compared with measurements in tap water. Fan beam DXA is a highly accurate and precise technique for measuring BMC and BMD in excised small animal bones. A physiological saline concentration in the water bath had a significant impact on BMC and area, but not on BMD, and should therefore be strictly controlled to avoid an underestimation of BMC.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11792592     DOI: 10.1016/s8756-3282(01)00641-x

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  8 in total

1.  Effect of endodontic cement on bone mineral density using serial dual-energy x-ray absorptiometry.

Authors:  Mohammad Ali Saghiri; Jafar Orangi; Nader Tanideh; Kamal Janghorban; Nader Sheibani
Journal:  J Endod       Date:  2014-01-03       Impact factor: 4.171

2.  [Feasibility of flat-panel volumetric computed tomography (fpVCT) in experimental small animal imaging of osteoporosis - initial experience].

Authors:  R Valencia; E K Stuermer; C Dullin; K P Herrmann; I Kluever; A Zaroban; S Sehmisch; M Funke; F Knollmann
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

3.  Precision of the Hologic DXA in the Assessment of Visceral Adipose Tissue.

Authors:  Elijah K Goldberg; Ellen B Fung
Journal:  J Clin Densitom       Date:  2019-03-20       Impact factor: 2.617

4.  Guidelines for Dual Energy X-Ray Absorptiometry Analysis of Trabecular Bone-Rich Regions in Mice: Improved Precision, Accuracy, and Sensitivity for Assessing Longitudinal Bone Changes.

Authors:  Jiayu Shi; Soonchul Lee; Michael Uyeda; Justine Tanjaya; Jong Kil Kim; Hsin Chuan Pan; Patricia Reese; Louis Stodieck; Andy Lin; Kang Ting; Jin Hee Kwak; Chia Soo
Journal:  Tissue Eng Part C Methods       Date:  2016-04-15       Impact factor: 3.056

5.  Correcting fan-beam magnification in clinical densitometry scans of growing subjects.

Authors:  Jacqueline H Cole; Jodi N Dowthwaite; Tamara A Scerpella; Marjolein C H van der Meulen
Journal:  J Clin Densitom       Date:  2009 Jul-Sep       Impact factor: 2.617

Review 6.  New imaging technologies in the diagnosis of osteoporosis.

Authors:  Galateia J Kazakia; Sharmila Majumdar
Journal:  Rev Endocr Metab Disord       Date:  2006-06       Impact factor: 9.306

7.  Characterization of Salvia miltiorrhiza ethanol extract as an anti-osteoporotic agent.

Authors:  Yan Cui; Bidur Bhandary; Anu Marahatta; Geum-Hwa Lee; Bo Li; Do-Sung Kim; Soo-Wan Chae; Hyung-Ryong Kim; Han-Jung Chae
Journal:  BMC Complement Altern Med       Date:  2011-11-28       Impact factor: 3.659

8.  Computed Tomography Osteodensitometry for Assessment of Bone Mineral Density of the Canine Head-Preliminary Results.

Authors:  Glynn Woods; Nicolas Israeliantz Gunz; Ian Handel; Tiziana Liuti; Richard J Mellanby; Tobias Schwarz
Journal:  Animals (Basel)       Date:  2021-05-14       Impact factor: 2.752

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.