Literature DB >> 11791930

Adsorption and dissolution behavior of human plasma fibronectin on thermally and chemically modified titanium dioxide particles.

D E MacDonald1, N Deo, B Markovic, M Stranick, P Somasundaran.   

Abstract

Titanium is known for its biocompatibility and is widely used in dental and orthopedic reconstructive surgery. There are reports that osteointegration of these implants is not optimal. The objective of this study was to modify titanium dioxide particles and examine the resultant effects on protein adsorption to these altered surfaces using a model cell binding protein, human plasma fibronectin (HPF). HPF is an important matrix glycoprotein that plays a major role in cell and protein attachment, Titanium dioxide surfaces were modified by heating the titanium dioxide powder at 800 degrees C for 1 h or treating with an oxidizing agent: peroxide in ammonium hydroxide followed by peroxide in hydrochloric acid. Oxidized and control samples were further treated with 9:1 butanol:water for 30 min. Brunauer-Emmett-Teller showed no change in particle surface area as a result of thermal or chemical treatment. Hydrophobicity increased with butanol treatment of titanium dioxide. Diffuse reflectance Fourier transform infrared spectroscopy showed the presence of -CH2 and -CH3 vibrations in the region of 2850-3000 cm(-1) for both the heated, butanol and peroxide/butanol-treated samples. The absence of increased C-O and O-C=O features as determined by electron spectroscopy for chemical analysis indicates that butanol adsorption is not occurring via an esterification mechanism. The interaction between butanol and pre-heated or peroxide-treated titanium dioxide may be one of association (weak electrostatic and/or Van der Waals forces) rather than direct ionic bonding. Maximum HPF adsorption on modified or unmodified titanium dioxide occurred within 30 min, with greater protein adsorption occurring on butanol-treated samples. Desorption was minimal with all modifications. Zeta potential measurements showed that HPF adsorption caused an increase in the negative zeta potential with the greatest change noted for the butanol-treated samples. These findings suggest that wettability and surface charge both play an important role in protein adsorption to titanium dioxide. Thus, by modifying the physico-chemical properties of titanium dioxide surfaces, it may be possible to alter protein adsorption and hence optimize cell attachment.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11791930     DOI: 10.1016/s0142-9612(01)00317-9

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  26 in total

Review 1.  Surface chemistry influences implant biocompatibility.

Authors:  Paul Thevenot; Wenjing Hu; Liping Tang
Journal:  Curr Top Med Chem       Date:  2008       Impact factor: 3.295

2.  How is wettability of titanium surfaces influenced by their preparation and storage conditions?

Authors:  D Scharnweber; F Schlottig; S Oswald; K Becker; H Worch
Journal:  J Mater Sci Mater Med       Date:  2009-10-23       Impact factor: 3.896

3.  Integrin and chemokine receptor gene expression in implant-adherent cells during early osseointegration.

Authors:  Omar Omar; Maria Lennerås; Sara Svensson; Felicia Suska; Lena Emanuelsson; Jan Hall; Ulf Nannmark; Peter Thomsen
Journal:  J Mater Sci Mater Med       Date:  2009-10-25       Impact factor: 3.896

4.  To cross-link or not to cross-link? Cross-linking associated foreign body response of collagen-based devices.

Authors:  Luis M Delgado; Yves Bayon; Abhay Pandit; Dimitrios I Zeugolis
Journal:  Tissue Eng Part B Rev       Date:  2015-03-12       Impact factor: 6.389

5.  Effects of coating a titanium alloy with fibronectin on the expression of osteoblast gene markers in the MC3T3 osteoprogenitor cell line.

Authors:  Bruce E Rapuano; Kyle M Hackshaw; Hannes C Schniepp; Daniel E MacDonald
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Sep-Oct       Impact factor: 2.804

6.  Titanium alloy surface oxide modulates the conformation of adsorbed fibronectin to enhance its binding to α(5) β(1) integrins in osteoblasts.

Authors:  Bruce E Rapuano; Jani J E Lee; Daniel E MacDonald
Journal:  Eur J Oral Sci       Date:  2012-05-08       Impact factor: 2.612

7.  Interrogating protonated/deuterated fibronectin fragment layers adsorbed to titania by neutron reflectivity and their concomitant control over cell adhesion.

Authors:  Lisa McIntosh; Christine Whitelaw; Agata Rekas; Stephen A Holt; Christopher F van der Walle
Journal:  J R Soc Interface       Date:  2015-06-06       Impact factor: 4.118

8.  Solid-State NMR and MD Study of the Structure of the Statherin Mutant SNa15 on Mineral Surfaces.

Authors:  Erika L Buckle; Arushi Prakash; Massimiliano Bonomi; Janani Sampath; Jim Pfaendtner; Gary P Drobny
Journal:  J Am Chem Soc       Date:  2019-01-24       Impact factor: 15.419

9.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy: evidence [corrected] for enhanced osteoinductive properties.

Authors:  Bruce E Rapuano; Herman Singh; Adele L Boskey; Stephen B Doty; Daniel E MacDonald
Journal:  J Cell Biochem       Date:  2013-08       Impact factor: 4.429

10.  Poly(NaSS) functionalization modulates the conformation of fibronectin and collagen type I to enhance osteoblastic cell attachment onto Ti6Al4V.

Authors:  Helena P Felgueiras; Sven D Sommerfeld; N Sanjeeva Murthy; Joachim Kohn; Véronique Migonney
Journal:  Langmuir       Date:  2014-08-01       Impact factor: 3.882

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.