Literature DB >> 11788701

Hemodynamics and wall mechanics of a compliance matching stent: in vitro and in vivo analysis.

Joel L Berry1, Emil Manoach, Choukri Mekkaoui, Pierre H Rolland, J E Moore, Alexander Rachev.   

Abstract

PURPOSE: Evidence is emerging that the abrupt compliance mismatch that exists at the junction between the stent ends and the host arterial wall disturbs both the vascular hemodynamics and the natural wall stress distribution. These stent-induced alterations are greatly reduced by smoothing the compliance mismatch between the stent and host vessel. A stent that provides this smooth transition in compliance, the compliance matching stent (CMS), has been developed. This study attempts to evaluate the hemodynamics and wall mechanical consequences of the CMS both in vitro and in vivo.
MATERIALS AND METHODS: Finite element analysis was used to assess the solid mechanical behavior (compliance and stress) of the CMS in a stent/artery hybrid structure. A similar analysis was performed with a Palmaz stent. In vivo hemodynamics and wall mechanical changes induced by the CMS were investigated in a swine model from direct measurements of flow, pressure, diameter, and histology in the stented segment of superficial femoral arteries after 7 days.
RESULTS: Finite element analysis showed that the abrupt compliance mismatch was substantially smoothed between the vessel portions with and without the stent with CMS segments. Circumferential stress was also markedly reduced with the CMS compared to other stent. The in vivo results showed that the CMS was efficient in compliance matching and did not dampen flow or pressure waves downstream the stent. Concurrent histology showed limited thrombus and inflammatory cell accumulation around the stent struts.
CONCLUSION: These results indicate that the stent/artery hybrid structure can be compliance matched with proper stent design and that this structure limits solid mechanical stress and hemodynamic disturbances. It remains to be seen whether compliance-matched vascular stents reduce in-stent restenosis.

Entities:  

Mesh:

Year:  2002        PMID: 11788701     DOI: 10.1016/s1051-0443(07)60015-3

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  16 in total

1.  The design of a reflectionless arterial prosthesis.

Authors:  Guy Richard Kol; Paul Woafo
Journal:  J Biol Phys       Date:  2010-08-17       Impact factor: 1.365

2.  Unconstrained recovery characterization of shape-memory polymer networks for cardiovascular applications.

Authors:  Christopher Michael Yakacki; Robin Shandas; Craig Lanning; Bryan Rech; Alex Eckstein; Ken Gall
Journal:  Biomaterials       Date:  2007-02-02       Impact factor: 12.479

3.  Cross-sectional pinching in human femoropopliteal arteries due to limb flexion, and stent design optimization for maximum cross-sectional opening and minimum intramural stresses.

Authors:  Anastasia Desyatova; William Poulson; Jason MacTaggart; Kaspars Maleckis; Alexey Kamenskiy
Journal:  J R Soc Interface       Date:  2018-08       Impact factor: 4.118

4.  Angiographically confirmed stent over expansion in the internal carotid artery during stenting: incidence, predictors, and outcomes.

Authors:  Masanori Tsutsumi; Hiroshi Aikawa; Kouhei Nii; Housei Etou; Kimiya Sakamoto; Hidenori Yoshida; Yoshihisa Matsumoto; Shuko Hamaguchi; Kiyoshi Kazekawa
Journal:  Neuroradiology       Date:  2011-07-06       Impact factor: 2.804

5.  Neointimal hyperplasia after stent placement across size-discrepant vessels in an animal study.

Authors:  Hisayuki Cho; Mineyoshi Nango; Yukimasa Sakai; Etsuji Sohgawa; Ken Kageyama; Shinichi Hamamoto; Toshiaki Kitayama; Akira Yamamoto; Yukio Miki
Journal:  Jpn J Radiol       Date:  2014-04-09       Impact factor: 2.374

6.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

7.  A novel arterial constitutive model in a commercial finite element package: Application to balloon angioplasty.

Authors:  Xuefeng Zhao; Yi Liu; Wei Zhang; Chong Wang; Ghassan S Kassab
Journal:  J Theor Biol       Date:  2011-06-15       Impact factor: 2.691

8.  Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression.

Authors:  Juan M Jiménez; Varesh Prasad; Michael D Yu; Christopher P Kampmeyer; Abdul-Hadi Kaakour; Pei-Jiang Wang; Sean F Maloney; Nathan Wright; Ian Johnston; Yi-Zhou Jiang; Peter F Davies
Journal:  J R Soc Interface       Date:  2014-02-19       Impact factor: 4.118

9.  Effects of stent design and atherosclerotic plaque composition on arterial wall biomechanics.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  J Endovasc Ther       Date:  2008-12       Impact factor: 3.487

10.  Mechanical modeling of stents deployed in tapered arteries.

Authors:  Lucas H Timmins; Clark A Meyer; Michael R Moreno; James E Moore
Journal:  Ann Biomed Eng       Date:  2008-10-10       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.