Comparison of the FemoStop device and manual pressure in reducing groin puncture site complications following coronary angioplasty and coronary stent placement.

S B Walker1, S Cleary, M Higgins.   

Abstract

This study compared two techniques, the FemoStop device (RADI Medical Systems, Uppsala, Sweden) and manual pressure, currently used by nurses to achieve haemostasis at the groin puncture site following removal of femoral arterial sheaths in patients following coronary angioplasty and coronary stent placement. Participants were randomly allocated the FemoStop device or manual pressure. Participants' groins were observed for evidence of complications including haemorrhage, haematoma formation and pseudoaneurysm following removal of the femoral arterial sheath and the following day. Of the 274 participants recruited into the study, 5.5% (n = 15) were unable to be included as a result of the absence of data on the Angioplasty Record of Care Form (n = 5) or excessive bleeding at the groin puncture site (n = 10). This left 259 eligible participants. Of these, 18.1% (n = 47) did not have their groin puncture site inspected by a post-procedural observer, thereby reducing the number of participants eligible to complete all stages of the study to 212. The results showed that the presence of a haematoma on removal of the femoral arterial sheath had a significant relationship with the type of treatment used, with those participants in the FemoStop device group showing a greater incidence of haematoma development at the time of sheath removal than those in the manual pressure group. No significant difference was detected in haematoma formation or bleeding between the two groups as a result of the risk factors identified in the literature, including participant anxiety, weight or anticoagulant therapy. There was not any significant difference between the two groups in reported pain during removal of the femoral arterial sheath; however, there was a significant distinction in the amount of time taken to achieve haemostasis. The results showed that haemostasis was achieved more quickly in those participants in the manual pressure group than those in the FemoStop group. The results of this research study indicate that although manual pressure achieved haemostasis more quickly than the FemoStop device, both methods are as effective in reducing groin complications in patients following removal of the femoral arterial sheath following coronary angioplasty and stent placement.

Entities:  

Mesh:

Year:  2001        PMID: 11785439     DOI: 10.1046/j.1440-172x.2001.00291.x

Source DB:  PubMed          Journal:  Int J Nurs Pract        ISSN: 1322-7114            Impact factor:   2.066


  5 in total

1.  A retrospective review on feasibility and safety of a new pneumatic compression device for femoral arteriotomy hemostasis.

Authors:  Minho Kang; Sung Wook Shin
Journal:  Korean J Radiol       Date:  2011-12-23       Impact factor: 3.500

2.  Usefulness and safety of the "God's Hand" pneumatic compression device for hemostasis in femoral catheterization.

Authors:  Sungwon Kim; Jae Hyun Kwon; Yoon Hee Han; Jeung Sook Kim
Journal:  Diagn Interv Radiol       Date:  2017 Jan-Feb       Impact factor: 2.630

Review 3.  Anticoagulation During AF Ablation: The Balance between Thromboembolism and Bleeding.

Authors:  Jennifer A Mears; Samuel J Asirvatham
Journal:  J Atr Fibrillation       Date:  2009-02-01

4.  Guidelines for Bystander First Aid 2016.

Authors:  Jen Heng Pek
Journal:  Singapore Med J       Date:  2017-07       Impact factor: 1.858

5.  Prospective comparison of angio-seal versus manual compression for hemostasis after neurointerventional procedures under systemic heparinization.

Authors:  H-F Wong; C-W Lee; Y-L Chen; Y-M Wu; H-H Weng; Y-H Wang; H-M Liu
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.