Literature DB >> 11781948

Effect of radiofrequency current on previously implanted pacemaker and defibrillator ventricular lead systems.

M C Burke1, D E Kopp, M Alberts, A Patel, A C Lin, J G Kall, M Arruda, P Mazeika, D J Wilber.   

Abstract

We compared the response of endocardial lead systems to radiofrequency (RF) current delivered during atrio-ventricular junction ablation (AVJA) for atrial fibrillation with uncontrolled ventricular rate in 107 patients. The mean age was 67 +/- 11 years and the mean ejection fraction 42 +/- 15%. Patients were divided into 3 groups based on the type of ventricular lead present at the time of ablation: a previously implanted defibrillator lead (group 3, n = 13), a previously implanted pacemaker lead (group 2, n = 46) or a temporary lead (group 1, n = 48), which was subsequently followed by a permanent lead implantation. During AVJA, a median of 5 RF applications (44 +/- 8 W) were given via 4-5-mm electrodes. All but 1 patient had right-sided lesions, while 6 patients also had left sided lesions. Ventricular pacing thresholds were evaluated immediately pre- and post-ablation at 24 hours and at 1 to 3 months. Increases in ventricular pacing voltage thresholds were noted in all 3 groups over time, with the greatest mean increase in group 3 patients: [table: see text]. A greater than 2-fold increase in pacing thresholds was observed only with previously implanted leads, usually within the first 48 hours. It occurred significantly more often in patients with group 3 (6/13 [46%]) compared to group 2 (6/46 [13%], odds ratio 7.6, P = 0.006). A progressive rise in pacing threshold required lead revision in 2/13 group 3 patients (15%) and 2/46 group 2 patients (4%). While RF current has only minor effects on pacing threshold in most patients with previously implanted ventricular lead systems, clinically important alterations requiring device reprogramming or lead revision may occur. Group 3 are significantly more vulnerable to RF current, though the mechanisms are unclear. Group 1 during AVJA, followed by permanent lead implantation appears advisable. Pts with a previously implanted group 3 who require AVJA should be monitored closely.

Entities:  

Mesh:

Year:  2001        PMID: 11781948     DOI: 10.1054/jelc.2001.28854

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  5 in total

Review 1.  [Perioperative management of patients with implanted pacemakers or cardioverter/defibrillators. Recommendations of the Austrian Society for Anaesthesiology, Resuscitation and Intensive Care Medicine, the Austrian Society for Cardiology and the Austrian Society for Surgery].

Authors:  H Gombotz; M Anelli Monti; N Leitgeb; M Nürnberg; B Strohmer
Journal:  Anaesthesist       Date:  2009-05       Impact factor: 1.041

2.  Radiofrequency and Cryo-Ablation Effect on Transvenous Pacing and Defibrillatory Lead Integrity: An In Vitro Study.

Authors:  Yousef H Darrat; Anuj Agarwal; Gustavo X Morales; Joseph Thompson; Ahmed Abdel-Latif; Kelly Waespe; Luigi DI Biase; Andrea Natale; Abhijit Patwardan; Claude-Samy Elayi
Journal:  J Cardiovasc Electrophysiol       Date:  2016-06-14

3.  Correlation of lifetime progress of atherosclerosis and morphologic markers of severity in humans: new tools for a more sensitive evaluation.

Authors:  Mara Lúcia da Fonseca Ferraz; Douglas Montielle Silva Nascimento; João Paulo Hanel Rorato; Ana Paula Espindula; Lívia Ferreira Oliveira; Luciana Santos Ramalho; Maria Helena Soares; Camila Lourencine Cavellani; Flávia Aparecida Oliveira; Sanívia Aparecida de Lima Pereira; Rosana Rosa Miranda Corrêa; Vicente de Paula Antunes Teixeira
Journal:  Clinics (Sao Paulo)       Date:  2012-09       Impact factor: 2.365

4.  Snaring of the right ventricular lead during cavotricuspid isthmus ablation.

Authors:  Yousef H Darrat; Morales X Gustavo; Cristen Kelly Waespe; John C Gurley; Claude S Elayi
Journal:  Clin Case Rep       Date:  2017-02-05

Review 5.  The Effects of Catheter Ablation on Permanent Pacemakers and Implantable Cardiac Defibrillators.

Authors:  Yousef H Darrat; Gustavo X Morales; Claude S Elayi
Journal:  J Innov Card Rhythm Manag       Date:  2017-03-15
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.