Development of internal controls for the Luminex instrument as part of a multiplex seven-analyte viral respiratory antibody profile.

Thomas B Martins1.   

Abstract

The ability of the Luminex system to simultaneously quantitate multiple analytes from a single sample source has proven to be a feasible and cost-effective technology for assay development. In previous studies, my colleagues and I introduced two multiplex profiles consisting of 20 individual assays into the clinical laboratory. With the Luminex instrument's ability to classify up to 100 distinct microspheres, however, we have only begun to realize the enormous potential of this technology. By utilizing additional microspheres, it is now possible to add true internal controls to each individual sample. During the development of a seven-analyte serologic viral respiratory antibody profile, internal controls for detecting sample addition and interfering rheumatoid factor (RF) were investigated. To determine if the correct sample was added, distinct microspheres were developed for measuring the presence of sufficient quantities of immunoglobulin G (IgG) or IgM in the diluted patient sample. In a multiplex assay of 82 samples, the IgM verification control correctly identified 23 out of 23 samples with low levels (<20 mg/dl) of this antibody isotype. An internal control microsphere for RF detected 30 out of 30 samples with significant levels (>10 IU/ml) of IgM RF. Additionally, RF-positive samples causing false-positive adenovirus and influenza A virus IgM results were correctly identified. By exploiting the Luminex instrument's multiplexing capabilities, I have developed true internal controls to ensure correct sample addition and identify interfering RF as part of a respiratory viral serologic profile that includes influenza A and B viruses, adenovirus, parainfluenza viruses 1, 2, and 3, and respiratory syncytial virus. Since these controls are not assay specific, they can be incorporated into any serologic multiplex assay.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11777827      PMCID: PMC119915          DOI: 10.1128/cdli.9.1.41-45.2002

Source DB:  PubMed          Journal:  Clin Diagn Lab Immunol        ISSN: 1071-412X


  7 in total

1.  Flow cytometric platform for high-throughput single nucleotide polymorphism analysis.

Authors:  J D Taylor; D Briley; Q Nguyen; K Long; M A Iannone; M S Li; F Ye; A Afshari; E Lai; M Wagner; J Chen; M P Weiner
Journal:  Biotechniques       Date:  2001-03       Impact factor: 1.993

2.  Multiplex analysis of heterophil antibodies in patients with indeterminate HIV immunoassay results.

Authors:  J H Willman; H R Hill; T B Martins; T D Jaskowski; E R Ashwood; C M Litwin
Journal:  Am J Clin Pathol       Date:  2001-05       Impact factor: 2.493

3.  Application of the luminex LabMAP in rapid screening for mutations in the cystic fibrosis transmembrane conductance regulator gene: A pilot study

Authors: 
Journal:  Clin Chem       Date:  2000-09       Impact factor: 8.327

4.  An evaluation of the effectiveness of three immunoglobulin G (IgG) removal procedures for routine IgM serological testing.

Authors:  T B Martins; T D Jaskowski; C L Mouritsen; H R Hill
Journal:  Clin Diagn Lab Immunol       Date:  1995-01

5.  Fluorescent microsphere-based readout technology for multiplexed human single nucleotide polymorphism analysis and bacterial identification.

Authors:  F Ye; M S Li; J D Taylor; Q Nguyen; H M Colton; W M Casey; M Wagner; M P Weiner; J Chen
Journal:  Hum Mutat       Date:  2001-04       Impact factor: 4.878

6.  Enhancement by N-hydroxysulfosuccinimide of water-soluble carbodiimide-mediated coupling reactions.

Authors:  J V Staros; R W Wright; D M Swingle
Journal:  Anal Biochem       Date:  1986-07       Impact factor: 3.365

7.  IgM-class rheumatoid factor interference in the solid-phase radioimmunoassay of rubella-specific IgM antibodies.

Authors:  O H Meurman; B R Ziola
Journal:  J Clin Pathol       Date:  1978-05       Impact factor: 3.411

  7 in total
  31 in total

1.  Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: determinations of a panel of nine cytokines in clinical sample culture supernatants.

Authors:  Nefertiti C dupont; Kehui Wang; Pathik D Wadhwa; Jennifer F Culhane; Edward L Nelson
Journal:  J Reprod Immunol       Date:  2005-08       Impact factor: 4.054

2.  Simultaneous detection of antibodies to six nonhuman-primate viruses by multiplex microbead immunoassay.

Authors:  Imran H Khan; Sara Mendoza; Joann Yee; Matthew Deane; Kodumudi Venkateswaran; Shan S Zhou; Peter A Barry; Nicholas W Lerche; Paul A Luciw
Journal:  Clin Vaccine Immunol       Date:  2006-01

Review 3.  Validation and quality control of protein microarray-based analytical methods.

Authors:  Larry J Kricka; Stephen R Master
Journal:  Mol Biotechnol       Date:  2007-08-03       Impact factor: 2.695

4.  Simultaneous serodetection of 10 highly prevalent mouse infectious pathogens in a single reaction by multiplex analysis.

Authors:  Imran H Khan; Lon V Kendall; Melanie Ziman; Scott Wong; Sara Mendoza; James Fahey; Stephen M Griffey; Stephen W Barthold; Paul A Luciw
Journal:  Clin Diagn Lab Immunol       Date:  2005-04

5.  Prenatal maternal immune disruption and sex-dependent risk for psychoses.

Authors:  J M Goldstein; S Cherkerzian; L J Seidman; J-A L Donatelli; A G Remington; M T Tsuang; M Hornig; S L Buka
Journal:  Psychol Med       Date:  2014-03-26       Impact factor: 7.723

6.  Cytokine network analysis of cerebrospinal fluid in myalgic encephalomyelitis/chronic fatigue syndrome.

Authors:  M Hornig; G Gottschalk; D L Peterson; K K Knox; A F Schultz; M L Eddy; X Che; W I Lipkin
Journal:  Mol Psychiatry       Date:  2015-03-31       Impact factor: 15.992

7.  An Optimized Hemagglutination Inhibition (HI) Assay to Quantify Influenza-specific Antibody Titers.

Authors:  Lukas Kaufmann; Mohammedyaseen Syedbasha; Dominik Vogt; Yvonne Hollenstein; Julia Hartmann; Janina E Linnik; Adrian Egli
Journal:  J Vis Exp       Date:  2017-12-01       Impact factor: 1.355

8.  A bead-based activity screen for small-molecule inhibitors of signal transduction in chronic myelogenous leukemia cells.

Authors:  Juliesta E Sylvester; Stephen J Kron
Journal:  Mol Cancer Ther       Date:  2010-04-27       Impact factor: 6.261

9.  Determination of serum IgG antibodies to Bacillus anthracis protective antigen in environmental sampling workers using a fluorescent covalent microsphere immunoassay.

Authors:  R E Biagini; D L Sammons; J P Smith; E H Page; J E Snawder; C A F Striley; B A MacKenzie
Journal:  Occup Environ Med       Date:  2004-08       Impact factor: 4.402

10.  Prerequisites for cytokine measurements in clinical trials with multiplex immunoassays.

Authors:  Wilco de Jager; Katarzyna Bourcier; Ger T Rijkers; Berent J Prakken; Vicki Seyfert-Margolis
Journal:  BMC Immunol       Date:  2009-09-28       Impact factor: 3.615

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.