Literature DB >> 11771980

Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging.

R Deichmann1, O Josephs, C Hutton, D R Corfield, R Turner.   

Abstract

Gradient-echo echo-planar imaging is a standard technique in functional magnetic resonance imaging (fMRI) experiments based on the blood oxygenation level-dependent (BOLD) effect. A major problem is the occurrence of susceptibility gradients near air/tissue interfaces. As a consequence, the detection of neuronal activation may be greatly compromised in certain brain areas, especially in the temporal lobes and in the orbitofrontal cortex. Common approaches to overcome this problem, such as z-shimming or the use of tailored radio frequency pulses, usually compensate only for susceptibility gradients in the slice selection direction. In the present study, the influence of susceptibility gradients in the phase encoding direction is investigated both theoretically and experimentally. It is shown that these gradients influence the effective echo time TE and may reduce considerably the local BOLD sensitivity, even in the case of acceptable image intensities. A compensation method is proposed and tested in an fMRI experiment based on a hypercapnic challenge. The results suggest that the compensation method allows for the detection of activation in brain areas which are usually unavailable for BOLD studies.

Mesh:

Substances:

Year:  2002        PMID: 11771980     DOI: 10.1006/nimg.2001.0985

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  76 in total

1.  Differences in functional MR imaging activation patterns associated with confrontation naming and responsive naming.

Authors:  Sarah Tomaszewki Farias; Gregory Harrington; Catherine Broomand; Maysud Seyal
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

2.  A 3 T event-related functional magnetic resonance imaging (fMRI) study of primary and secondary gustatory cortex localization using natural tastants.

Authors:  Marion Smits; Ronald R Peeters; Paul van Hecke; Stefan Sunaert
Journal:  Neuroradiology       Date:  2006-11-14       Impact factor: 2.804

3.  High resolution single-shot EPI at 7T.

Authors:  Oliver Speck; J Stadler; M Zaitsev
Journal:  MAGMA       Date:  2007-11-01       Impact factor: 2.310

4.  K-space spatial low-pass filters can increase signal loss artifacts in Echo-Planar Imaging.

Authors:  E C Caparelli; D Tomasi
Journal:  Biomed Signal Process Control       Date:  2008-01       Impact factor: 3.880

5.  Learning affective values for faces is expressed in amygdala and fusiform gyrus.

Authors:  Predrag Petrovic; Raffael Kalisch; Mathias Pessiglione; Tania Singer; Raymond J Dolan
Journal:  Soc Cogn Affect Neurosci       Date:  2008-02-08       Impact factor: 3.436

6.  Optimized EPI for fMRI using a slice-dependent template-based gradient compensation method to recover local susceptibility-induced signal loss.

Authors:  Jochen Rick; Oliver Speck; Simon Maier; Oliver Tüscher; Olaf Dössel; Jürgen Hennig; Maxim Zaitsev
Journal:  MAGMA       Date:  2010-05-21       Impact factor: 2.310

7.  Ventral striatal network connectivity reflects reward learning and behavior in patients with Parkinson's disease.

Authors:  Kalen Petersen; Nelleke Van Wouwe; Adam Stark; Ya-Chen Lin; Hakmook Kang; Paula Trujillo-Diaz; Robert Kessler; David Zald; Manus J Donahue; Daniel O Claassen
Journal:  Hum Brain Mapp       Date:  2017-10-31       Impact factor: 5.038

8.  Improved image reconstruction for partial Fourier gradient-echo echo-planar imaging (EPI).

Authors:  Nan-kuei Chen; Koichi Oshio; Lawrence P Panych
Journal:  Magn Reson Med       Date:  2008-04       Impact factor: 4.668

9.  Echo time dependence of BOLD fMRI studies of the piriform cortex.

Authors:  Rainer Kopietz; Jessica Albrecht; Jennifer Linn; Olga Pollatos; Andrea Anzinger; Tim Wesemann; Gunther Fesl; Thomas Stephan; Hartmut Brückmann; Martin Wiesmann
Journal:  Klin Neuroradiol       Date:  2009-11-21

10.  Interleaved spiral-in/out with application to functional MRI (fMRI).

Authors:  Christine S Law; Gary H Glover
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.