Literature DB >> 11771598

Propofol anaesthesia via target controlled infusion or manually controlled infusion: effects on the bispectral index as a measure of anaesthetic depth.

T Gale1, K Leslie, M Kluger.   

Abstract

Target controlled infusions (TCI) of propofol allow anaesthetists to target constant blood concentrations and respond promptly to signs of inappropriate anaesthetic depth. Studies comparing propofol TCI with manually controlled infusion (MCI) reported similar control of anaesthesia, but did not use an objective measure of anaesthetic depth. We therefore tested whether the Bispectral Index (BIS), an electroencephalographic (EEG) variable, is more stable during propofol TCI or MCI. Forty patients received midazolam and fentanyl before induction and were randomized to TCI or MCI. Target propofol concentrations in the TCI group were 3 to 8 microg/ml. The MCI group received propofol bolus (approximately 2 mg/kg) and infusion (3 to 10 mg/kg/h). Neuromuscular blockade was achieved with rocuronium. Following endotracheal intubation, nitrous oxide (66%) in oxygen was delivered and propofol infusion and fentanyl boluses were titrated against clinical signs. Blood pressure, heart rate and EEG were recorded, although the anaesthetist was blind to BIS values. The ideal BIS for general anaesthesia was defined as 50. Performance error, absolute performance error, wobble and divergence of BIS, and maximum changes in blood pressure and heart rate were compared using two-sample t-tests or rank-sum tests where appropriate. There was no difference in absolute performance errors during maintenance of anaesthesia with propofol TCI or MCI (23 +/- 11% vs 23 +/- 9%; P=0.97). The two groups did not differ significantly in performance error, wobble, divergence on haemodynamic changes. We conclude that TCI and MCI result in similar depth of anaesthesia and haemodynamic stability when titrated against traditional clinical signs.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11771598     DOI: 10.1177/0310057X0102900602

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

Review 1.  Induction of anaesthesia: a guide to drug choice.

Authors:  Nathalie Nathan; Isabelle Odin
Journal:  Drugs       Date:  2007       Impact factor: 9.546

2.  [Propofol administration systems. Handling, hemodynamics and propofol consumption].

Authors:  J G Triem; K D Röhm; J Boldt; S N Piper
Journal:  Anaesthesist       Date:  2009-03       Impact factor: 1.041

Review 3.  Anaesthetic interventions for prevention of awareness during surgery.

Authors:  Anthony G Messina; Michael Wang; Marshall J Ward; Chase C Wilker; Brett B Smith; Daniel P Vezina; Nathan Leon Pace
Journal:  Cochrane Database Syst Rev       Date:  2016-10-18

Review 4.  Medical devices for the anesthetist: current perspectives.

Authors:  Jerry Ingrande; Hendrikus Jm Lemmens
Journal:  Med Devices (Auckl)       Date:  2014-03-25

5.  Determination of the appropriate propofol infusion rate for outpatient upper gastrointestinal endoscopy-a randomized prospective study.

Authors:  Qiongzhen Li; Qinghe Zhou; Wangpin Xiao; Hongmei Zhou
Journal:  BMC Gastroenterol       Date:  2016-04-26       Impact factor: 3.067

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.