Literature DB >> 11768498

Functional CT imaging of angiogenesis in rabbit VX2 soft-tissue tumour.

T G Purdie1, E Henderson, T Y Lee.   

Abstract

Functional parameters such as blood flow (BF), microvessel permeability surface area product (PS), blood volume (BV) and mean transit time (MTT) are physiological markers related to the changes associated with angiogenesis. In the current study we present a functional CT technique for the simultaneous measurement of these four functional parameters and the display of each parameter as a functional image over an entire tissue slice. New Zealand White rabbits with implanted VX2 thigh tumours were scanned using CT with contrast media injection. The ex vivo method of radioactive microspheres was used to evaluate the accuracy of BF measurements with the functional CT technique. There was a significant linear correlation (R = 0.96) between regional CT and microsphere-measured BF values, with a slope not significantly different from unity (0.98 +/- 0.02, P < 0.0001). The precision of our CT technique was determined by the repeated scanning under steady-state conditions. The precision of CT-measured BF, PS. BV and MTT was 14%, 18%, 20% and 24%, respectively. In conclusion, BF can be measured accurately and BF, PS, BV and MTT reproducibly using our functional CT technique. Functional CT can be readily incorporated into existing imaging protocols to assess tumour angiogenesis.

Entities:  

Mesh:

Year:  2001        PMID: 11768498     DOI: 10.1088/0031-9155/46/12/307

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Perfusion CT assessment of tissue hemodynamics following hepatic arterial infusion of increasing doses of angiotensin II in a rabbit liver tumor model.

Authors:  Kenneth C Wright; Murali K Ravoori; Katherine A Dixon; Lin Han; Sheela P Singh; Ping Liu; Sanjay Gupta; Valen E Johnson; Zuxing Kan; Vikas Kundra
Journal:  Radiology       Date:  2011-06-01       Impact factor: 11.105

2.  Dynamic contrast-enhanced micro-CT on mice with mammary carcinoma for the assessment of antiangiogenic therapy response.

Authors:  Fabian Eisa; Robert Brauweiler; Martin Hupfer; Tristan Nowak; Laura Lotz; Inge Hoffmann; David Wachter; Ralf Dittrich; Matthias W Beckmann; Gregor Jost; Hubertus Pietsch; Willi A Kalender
Journal:  Eur Radiol       Date:  2011-11-10       Impact factor: 5.315

3.  CT perfusion in solid-body tumours. Part I: Technical issues.

Authors:  G Petralia; L Preda; G D'Andrea; S Viotti; L Bonello; R De Filippi; M Bellomi
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

4.  Longitudinal in vivo monitoring of rodent glioma models through thinned skull using laser speckle contrast imaging.

Authors:  Abhishek Rege; Alan C Seifert; Dan Schlattman; Yu Ouyang; Khan W Li; Luca Basaldella; Henry Brem; Betty M Tyler; Nitish V Thakor
Journal:  J Biomed Opt       Date:  2012-12       Impact factor: 3.170

Review 5.  Perfusion CT imaging of brain tumors: an overview.

Authors:  R Jain
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-04       Impact factor: 3.825

6.  Perfusion CT estimates photosensitizer uptake and biodistribution in a rabbit orthotopic pancreatic cancer model: a pilot study.

Authors:  Jonathan T Elliott; Kimberley S Samkoe; Jason R Gunn; Errol E Stewart; Timothy B Gardner; Kenneth M Tichauer; Ting-Yim Lee; P Jack Hoopes; Stephen P Pereira; Tayyaba Hasan; Brian W Pogue
Journal:  Acad Radiol       Date:  2015-02-14       Impact factor: 3.173

7.  Experimental study of multi-slice spiral CT perfusion imaging in VX2 soft-tissue tumor of rabbits.

Authors:  Jingfeng Zhang; Renfa Wang; Min Wang; Yonggang Li; Haitao Yang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006

8.  Assessing perfusion changes during whole brain irradiation for patients with cerebral metastases.

Authors:  Barbara-Ann M Millar; Thomas G Purdie; Ivan Yeung; Gregory R Pond; Susan Billingsley; Rebecca Wong; Peiman Haddad; C Shun Wong; Normand Laperriere
Journal:  J Neurooncol       Date:  2005-02       Impact factor: 4.130

9.  Quantitative estimation of permeability surface-area product in astroglial brain tumors using perfusion CT and correlation with histopathologic grade.

Authors:  R Jain; S K Ellika; L Scarpace; L R Schultz; J P Rock; J Gutierrez; S C Patel; J Ewing; T Mikkelsen
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

10.  Can perfusion CT assessment of primary colorectal adenocarcinoma blood flow at staging predict for subsequent metastatic disease? A pilot study.

Authors:  Vicky Goh; Steve Halligan; David M Wellsted; Clive I Bartram
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.