Literature DB >> 11758985

Laser in situ keratomileusis for hyperopia and hyperopic astigmatism with the Nidek EC-5000 Excimer laser.

A Pineda-Fernández1, L Rueda, D Huang, J Nur, J Jaramillo.   

Abstract

PURPOSE: We evaluated the efficacy, predictability, stability, and safety of laser in situ keratomileusis (LASIK) for hyperopia and hyperopic astigmatism.
METHODS: A retrospective study was performed for 92 eyes of 62 consecutive patients to evaluate uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA) and manifest refraction before and 3 and 6 months after LASIK (Moria LSK-ONE microkeratome, Nidek EC-5000 excimer laser). Eyes were divided into groups: Group 1 (low hyperopia) for spherical correction of +1.00 to +3.00 D (22 eyes), Group 2 (low hyperopic astigmatism) for toric correction with spherical equivalent refraction of +1.00 to +3.00 D (18 eyes), Group 3 (moderate hyperopia) for spherical correction of +3.25 to +6.00 D (10 eyes), and Group 4 (moderate hyperopic astigmatism) for toric correction with spherical equivalent refraction between +3.25 and +6.00 D (18 eyes).
RESULTS: At 3 and 6 months after LASIK, 68 eyes (73.9%) were available for follow-up examination. Percentage of eyes with a spherical equivalent refraction within +/-0.50 D of emmetropia for Group 1 was 54.5% (12 eyes); Group 2, 50% (9 eyes); Group 3, 40% (4 eyes), and Group 4, 38.8% (7 eyes). UCVA > or =20/20 in Group 1 was 14% and in Groups 2, 3, and 4, 0%. One eye (5.5%) lost two lines of BSCVA.
CONCLUSION: LASIK with the Moria LSK-ONE microkeratome and the Nidek EC-5000 excimer laser reduced low and moderate hyperopia and was within +/-0.50 D of target outcome in approximately 50% of eyes. Undercorrection was evident in all groups. The procedure was safe.

Entities:  

Mesh:

Year:  2001        PMID: 11758985     DOI: 10.3928/1081-597X-20011101-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Conductive keratoplasty: a radiofrequency-based technique for the correction of hyperopia.

Authors:  Marguerite B McDonald
Journal:  Trans Am Ophthalmol Soc       Date:  2005

2.  Role of percent peripheral tissue ablated on refractive outcomes following hyperopic LASIK.

Authors:  George Fatseas; Fiona Stapleton; Patrick Versace
Journal:  PLoS One       Date:  2017-02-02       Impact factor: 3.240

3.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

4.  Topography-guided hyperopic and hyperopic astigmatism femtosecond laser-assisted LASIK: long-term experience with the 400 Hz eye-Q excimer platform.

Authors:  Anastasios John Kanellopoulos
Journal:  Clin Ophthalmol       Date:  2012-06-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.