Literature DB >> 11755728

Direct MR arthrography of the shoulder: 2D vs. 3D gradient-echo imaging.

R Wutke1, F A Fellner, C Fellner, R Stangl, M Dobritz, W A Bautz.   

Abstract

The aim of this study was to determine the value of a fat suppressed 3D gradient-echo sequence (GRE) data set in comparison to a 2D GRE sequence in direct MR arthrography of the shoulder. For this purpose we examined 50 consecutive patients with subacute or chronic disorders of the shoulder using a 1.5 T scanner: Transverse T1-weighted 2D (slice thickness 4 mm) and 3D GRE (slice thickness 1.5 mm reconstructed from 3 mm), oblique coronal T2- and T1-weighted turbo spin-echo (TSE) and sagittal T1-weighted TSE with fat saturation were applied. Visual image analysis of anatomical and pathological structures was performed by two independent observers. A correlation to surgical results was available in 21 patients. Transverse GRE sequences were well suited for analysis of the anterior/posterior labrum, the middle glenohumeral ligament, and cartilage. 3D GRE with fat suppression was slightly superior to 2D GRE without fat suppression in the evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament, whereas for cartilage no significant differences were found between both sequences. Concerning pathological findings, in most of the cases 2D delivered the same results as 3D. In conclusion, a T1-weighted 3D GRE data set with fat saturation in transverse orientation may be useful for evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament. However, similar measured slice thickness of 3 mm-even if interpolated to 1.5 mm-compared to a 2D sequence with 4 mm does not provide significant diagnostic advantages.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11755728     DOI: 10.1016/s0730-725x(01)00462-3

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences.

Authors:  Joon-Yong Jung; Won-Hee Jee; Michael Y Park; So-Yeon Lee; Yang-Soo Kim
Journal:  Skeletal Radiol       Date:  2012-02-10       Impact factor: 2.199

2.  Evaluation of lumber nerve root compression using thin-slice thickness coronal magnetic resonance imaging: three-dimensional fat-suppressed multi-shot balanced non-steady-state free precession versus three-dimensional T1-weighted spoiled gradient-recalled echo.

Authors:  Keizo Tanitame; Nobuko Tanitame; Chihiro Tani; Masaki Ishikawa; Miyuki Takasu; Shuji Date; Keiko Otani; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2011-09-29       Impact factor: 2.374

3.  Gradient-recalled echo sequences in direct shoulder MR arthrography for evaluating the labrum.

Authors:  Marc J Lee; Kambiz Motamedi; Kira Chow; Leanne L Seeger
Journal:  Skeletal Radiol       Date:  2007-10-26       Impact factor: 2.199

4.  Comparison with Magnetic Resonance Three-Dimensional Sequence for Lumbar Nerve Root with Intervertebral Foramen.

Authors:  Hiroyuki Takashima; Tsuneo Takebayashi; Hiroki Shishido; Mitsunori Yoshimoto; Rui Imamura; Yoshihiro Akatsuka; Yoshinori Terashima; Hiroyoshi Fujiwara; Masateru Nagae; Toshikazu Kubo; Toshihiko Yamashita
Journal:  Asian Spine J       Date:  2016-02-16
  4 in total