Multiple field of view MR fluoroscopy.

Pelin Aksit1, J Andrew Derbyshire, Jean-Michel Serfaty, Ergin Atalar.   

Abstract

This work describes a real-time imaging and visualization technique that allows multiple field of view (FOV) imaging. A stream of images from a single receiver channel can be reconstructed at multiple FOVs within each image frame. Alternately, or in addition, when multiple receiver channels are available, image streams from each channel can be independently reconstructed at multiple FOVs. The implementation described here provides for real-time visualization of the placement of guidewires and catheters on a dynamic roadmap during interventional procedures. The loopless catheter antenna, an electrically active intravascular probe, was used for MR signal reception. In 2D projection images, the catheter and surrounding structures within its diameter of sensitivity appear as bright signal. The simplicity of the resulting images allows very-narrow-FOV imaging to decrease imaging time. Very-narrow-FOV images are acquired on MR receiver channels that collect guidewire or catheter data. These very-narrow-FOV images provide very high frame rate continuous, real-time imaging of the interventional devices (25 fps). Large-FOV images are formed from receiver channels that collect anatomical data from standard imaging surface coils, and simultaneously provide a dynamic, frequently updated roadmap. These multiple-FOV images are displayed together, improving visualization of interventional device placement. Copyright 2002 Wiley-Liss, Inc.

Mesh:

Year:  2002        PMID: 11754442     DOI: 10.1002/mrm.10035

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Real-time accelerated interactive MRI with adaptive TSENSE and UNFOLD.

Authors:  Michael A Guttman; Peter Kellman; Alexander J Dick; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-08       Impact factor: 4.668

2.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

Review 3.  Real-time, Interactive MRI for cardiovascular interventions.

Authors:  Elliot R McVeigh; Michael A Guttman; Peter Kellman; Amish N Raval; Robert J Lederman
Journal:  Acad Radiol       Date:  2005-09       Impact factor: 3.173

4.  Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings.

Authors:  Michael A Guttman; Cenghizhan Ozturk; Amish N Raval; Venkatesh K Raman; Alexander J Dick; Ranil DeSilva; Parag Karmarkar; Robert J Lederman; Elliot R McVeigh
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

5.  Visualization of active devices and automatic slice repositioning ("SnapTo") for MRI-guided interventions.

Authors:  Ashvin K George; J Andrew Derbyshire; Haris Saybasili; Christina E Saikus; Ozgur Kocaturk; Michael A Guttman; Elliot R McVeigh; Robert J Lederman; Anthony Z Faranesh
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

Review 6.  Magnetic resonance imaging-guided vascular interventions.

Authors:  Cengizhan Ozturk; Michael Guttman; Elliot R McVeigh; Robert J Lederman
Journal:  Top Magn Reson Imaging       Date:  2005-10

7.  Real-time MR imaging-guided laser atrial septal puncture in swine.

Authors:  Abdalla A Elagha; Ozgur Kocaturk; Michael A Guttman; Cengizhan Ozturk; Ann H Kim; George W Burton; June H Kim; Venkatesh K Raman; Amish N Raval; Victor J Wright; William H Schenke; Elliot R McVeigh; Robert J Lederman
Journal:  J Vasc Interv Radiol       Date:  2008-07-21       Impact factor: 3.464

Review 8.  Interventional cardiovascular magnetic resonance: still tantalizing.

Authors:  Kanishka Ratnayaka; Anthony Z Faranesh; Michael A Guttman; Ozgur Kocaturk; Christina E Saikus; Robert J Lederman
Journal:  J Cardiovasc Magn Reson       Date:  2008-12-29       Impact factor: 5.364

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.