Literature DB >> 11748395

Internal jugular vein occlusion test for rapid diagnosis of misplaced subclavian vein catheter into the internal jugular vein.

S P Ambesh1, J C Pandey, P K Dubey.   

Abstract

BACKGROUND: During subclavian vein catheterization, the most common misplacement of the catheter is cephalad, into the ipsilateral internal jugular vein (IJV). This can be detected by chest radiography. However, after any repositioning of the catheter, subsequent chest radiography is required. In an effort to simplify the detection of a misplaced subclavian vein catheter, the authors assessed a previously published detection method.
METHODS: One hundred adult patients scheduled for subclavian vein cannulation were included in this study. After placement of subclavian vein catheter, chest radiography was performed. While the x-ray film was being processed, the authors performed an IJV occlusion test by applying external pressure on the IJV for approximately 10 s in the supraclavicular area and observed the change in central venous pressure and its waveform pattern. The observations thus obtained were compared with the position of catheter in chest radiographs, and the sensitivity and specificity of this method were evaluated using a 2 x 2 table.
RESULTS: In 96 patients, subclavian vein cannulation was successfully performed. In four patients, cannulation was unsuccessful; therefore, these patients were excluded from the study. There were six misplacements of venous catheters as detected by radiography. In five (5.2%) patients, the catheter tip was located in the ipsilateral IJV, and in one (1.02%), the catheter tip was located in the contralateral subclavian vein. In the patients who had a misplaced catheter into the IJV, IJV occlusion test results were positive, with an increase of 3-5 mmHg in central venous pressure, whereas the test results were negative in patients who had normally placed catheters or misplacement of a catheter other than in the IJV. There were no false-positive or false-negative test results.
CONCLUSION: The IJV occlusion test successfully detects the misplacement of subclavian vein catheter into the IJV. However, it does not detect any other misplacement. The test may allow avoidance of repeated exposure to x-rays after catheter insertion and repositioning.

Entities:  

Mesh:

Year:  2001        PMID: 11748395     DOI: 10.1097/00000542-200112000-00016

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  11 in total

1.  Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables.

Authors:  Wen-qiao Yu; Yun Zhang; Shao-yang Zhang; Zhong-yan Liang; Shui-qiao Fu; Jia Xu; Ting-bo Liang
Journal:  J Zhejiang Univ Sci B       Date:  2016-01       Impact factor: 3.066

2.  Late migration of subclavian venous catheter after initial correct placement.

Authors:  Vanita Ahuja; Hemant Bhaga
Journal:  J Anesth       Date:  2009-05-15       Impact factor: 2.078

3.  Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography.

Authors:  Maurizio Zanobetti; Alessandro Coppa; Federico Bulletti; Serena Piazza; Peyman Nazerian; Alberto Conti; Francesca Innocenti; Stefano Ponchietti; Sofia Bigiarini; Aurelia Guzzo; Claudio Poggioni; Beatrice Del Taglia; Yuri Mariannini; Riccardo Pini
Journal:  Intern Emerg Med       Date:  2012-12-16       Impact factor: 3.397

4.  Misdirected central venous catheter.

Authors:  Nita D'souza; Babita Gupta; Chhavi Sawhney; Anurag Chaturvedi
Journal:  J Emerg Trauma Shock       Date:  2010-04

5.  Coiling of Central Venous Catheter: A Rare and Preventable Complication.

Authors:  Nitin Hayaran; Nitin Goyal; Sudipta Joy; Aruna Jain
Journal:  Anesth Essays Res       Date:  2017 Jul-Sep

6.  Intracranial entrapment of a haemodialysis catheter guidewire.

Authors:  Natasha Hemicke Langer; Lars Hein; Morten Heiberg Bestle
Journal:  BMJ Case Rep       Date:  2020-08-25

7.  The influence of the direction of J-tip on the placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial.

Authors:  Ah-Young Oh; Young-Tae Jeon; Eun-Joo Choi; Jung-Hee Ryu; Jung-Won Hwang; Hee-Pyoung Park; Sang-Hwan Do
Journal:  BMC Anesthesiol       Date:  2014-02-28       Impact factor: 2.217

8.  Malposition of Central Venous Catheter: Presentation and Management.

Authors:  Lin Wang; Zhang-Suo Liu; Chang-An Wang
Journal:  Chin Med J (Engl)       Date:  2016-01-20       Impact factor: 2.628

9.  A quantitative analysis of the relation between the clavicular tilt angle and subclavian central venous catheter misplacement.

Authors:  Hoe-Hwan Jeong; Jung-Hoon Yoon; Sungho Oh; Je Hwan Won; Young-Gi Min; Nikolaus Gravenstein; Sang-Cheon Choi
Journal:  Clin Exp Emerg Med       Date:  2014-12-31

10.  Saline Flush versus Chest x ray in Confirmation of Central Venous Catheter Placement; a Diagnostic Accuracy Study.

Authors:  Mehrdad Esmailian; Reza Azizkhani; Nazila Najafi
Journal:  Emerg (Tehran)       Date:  2017-08-08