Literature DB >> 11747883

Contact area and pressure distribution in the feline patellofemoral joint under physiologically meaningful loading conditions.

A L Clark1, W Herzog, T R Leonard.   

Abstract

The purpose of this study was to determine contact area and mean and peak pressures in the healthy feline patellofemoral joint over the complete range of possible applied force. Furthermore, we wanted to improve upon the repeatability of previous measurements while maximizing the physiological relevance of the results obtained. The patellae and femora were secured in a loading frame approximating an in situ loading configuration. Low- and medium-grade Fuji film was used to assess patellofemoral contact area and pressure distribution, respectively. Constant force was applied to the patellofemoral joints for 2s (short duration trials) or 5min (long duration trials). For the short duration trials, contact area was shown to increase logarithmically with the force applied. In contrast, mean and peak pressures increased linearly with force. Furthermore, the rate of increase of peak pressure with force was approximately three times greater than that of mean pressure. For the long duration trials, contact area increased up to 33% compared to the short duration trials. This effect could no longer be detected with our approach after an unloading period of 5-10s. Increasing contact area is one mechanism that the feline patellofemoral joint may use to regulate the pressures experienced by the cartilage as the force applied to the joint increases. The attenuation of external forces inside a joint is achieved by the specific geometry of the articulating surfaces and the viscoelastic properties of the articular cartilage. It likely represents a natural protection of joints to high external load magnitudes.

Entities:  

Mesh:

Year:  2002        PMID: 11747883     DOI: 10.1016/s0021-9290(01)00165-8

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

Review 1.  Muscle dysfunction versus wear and tear as a cause of exercise related osteoarthritis: an epidemiological update.

Authors:  Ian Shrier
Journal:  Br J Sports Med       Date:  2004-10       Impact factor: 13.800

2.  Sensate scaffolds can reliably detect joint loading.

Authors:  C L Bliss; J A Szivek; B C Tellis; D S Margolis; A B Schnepp; J T Ruth
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-04       Impact factor: 3.368

3.  Tibiofemoral loss of contact area but no changes in peak pressures after meniscectomy in a Lapine in vivo quadriceps force transfer model.

Authors:  Andre Leumann; Rafael Fortuna; Tim Leonard; Victor Valderrabano; Walter Herzog
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-02       Impact factor: 4.342

4.  Two-dimensional strain fields on the cross-section of the bovine humeral head under contact loading.

Authors:  Clare E Canal; Clark T Hung; Gerard A Ateshian
Journal:  J Biomech       Date:  2008-10-25       Impact factor: 2.712

Review 5.  The role of muscles in joint adaptation and degeneration.

Authors:  W Herzog; D Longino; A Clark
Journal:  Langenbecks Arch Surg       Date:  2003-09-20       Impact factor: 3.445

6.  Imaging features in incident radiographic patellofemoral osteoarthritis: the Beijing Shunyi osteoarthritis (BJS) study.

Authors:  Yudian Qiu; Chutong Lin; Qiang Liu; Qunjie Zhong; Ke Tao; Dan Xing; Hu Li; Jianhao Lin
Journal:  BMC Musculoskelet Disord       Date:  2019-08-07       Impact factor: 2.362

  6 in total