Literature DB >> 11747148

Multicentre, prospective, randomized trial of 4 vs. 6 French catheters in 410 patients undergoing coronary angiography.

D M Todd1, P J Hubner, N Hudson, J Sarma, A J McCance, J Caplin.   

Abstract

The aim of this study was to assess the quality of angiograms obtained using 4 Fr catheters compared with 6 Fr catheters, the ease of use of the 4 Fr catheters, and the safety of patient mobilization 1 hr following 4 Fr angiography. Details of catheter performance and procedural details were recorded at the time of the angiogram. The angiographic images were scored on the quality and completeness of vessel opacification throughout systole and diastole. A total of 410 patients were recruited. There was no difference between 4 and 6 Fr for procedural variables. All angiograms were considered to be of diagnostic quality. The angiographic scores for the right coronary artery and left ventricular injections were no different between 4 and 6 Fr. However, the angiographic scores for the left anterior descending and circumflex arteries were lower with 4 than with 6 Fr (both P < 0.05). Patients who had 4 Fr angiography mobilized safely at 1 hr and reported significantly less discomfort and bruising than 6 Fr patients. Good-quality diagnostic coronary angiograms can be achieved using 4 Fr catheters with the advantage of earlier postprocedural mobilization and reduced discomfort and bruising for the patient. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11747148     DOI: 10.1002/ccd.1283

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  2 in total

1.  Novel diagnostic catheter specifically designed for both coronary arteries via the right transradial approach. A prospective, randomized trial of Tiger II vs. Judkins catheters.

Authors:  Seong-Man Kim; Dae-Kyeong Kim; Doo-Il Kim; Dong-Soo Kim; Seung-Jae Joo; Jae-Woo Lee
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

2.  Evaluation of the usefulness of coronary catheters and 4 Fr insertion sets for transradial access coronarography in comparison with catheters and 5 Fr sets.

Authors:  Piotr Chodór; Stanisław Morawski; Sylwia Sulik-Gajda; Nela Ramus; Jacek Kowalczyk; Grzegorz Honisz; Krzysztof Wilczek; Beata Sredniawa; Zbigniew Kalarus
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-11-18       Impact factor: 1.426

  2 in total