Literature DB >> 11746105

Doublet discrimination in DNA cell-cycle analysis.

R P Wersto1, F J Chrest, J F Leary, C Morris, M A Stetler-Stevenson, E Gabrielson.   

Abstract

Differences in doublet analysis have the potential to alter DNA cell-cycle measurements. The techniques for doublet determination are often used interchangeably without regard for the complexity in cell shapes and sizes of biological specimens. G(0/1) doublets were identified and quantitated using fluorescence height versus area and fluorescence width versus area pulse measurements, by enumerating the proportion of G(2) + M cells that lack cyclin B1 immunoreactivity, and modeled in the DNA histograms by software algorithms. These techniques were tested on propidium iodide-stained whole epithelial cells or nuclei from asynchronous cultures, or after exposure to chemotherapeutic agents that induced cell-cycle arrest and were extended to human breast tumor specimens having DNA diploid patterns. G(0/1) doublets were easily discernible from G(2) + M singlets in cells or nuclei that are generally homogenous and spherical in shape. Doublet discrimination based on pulse processing or cyclin B1 measurements was nonconcordant in some nonspherical cell types and in cells following cell cycle arrest. Significant differences in G(0/1) doublet estimates were observed in breast tumor specimens (n = 50), with estimates based on pulse width twice those of pulse height and nearly five times greater than computer estimates. Differences between techniques are attributed to difficulties in the separation of the boundaries between G(0/1) doublets and G(2) + M singlet populations in biologically heterogeneous specimens. To improve reproducibility and enhance standardization among laboratories performing cell cycle analysis in experimental cell systems and in human breast tumors, doublet discrimination analysis should best be accomplished by computer modeling. Shape and size heterogeneity of tumor and arrested cells using pulse-processing can lead to errors and make interlaboratory comparison difficult. Published 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11746105     DOI: 10.1002/cyto.1171

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  69 in total

1.  A rapid and optimization-free procedure allows the in vivo detection of subtle cell cycle and ploidy alterations in tissues by flow cytometry.

Authors:  Christina Heinlein; Wolfgang Deppert; Antony W Braithwaite; Daniel Speidel
Journal:  Cell Cycle       Date:  2010-09-01       Impact factor: 4.534

2.  Microtubule-dependent movement of late endocytic vesicles in vitro: requirements for Dynein and Kinesin.

Authors:  Eustratios Bananis; Sangeeta Nath; Kristie Gordon; Peter Satir; Richard J Stockert; John W Murray; Allan W Wolkoff
Journal:  Mol Biol Cell       Date:  2004-06-04       Impact factor: 4.138

3.  Intra-hematopoietic cell fusion as a source of somatic variation in the hematopoietic system.

Authors:  Amy M Skinner; Markus Grompe; Peter Kurre
Journal:  J Cell Sci       Date:  2012-03-05       Impact factor: 5.285

4.  A systematic screen for transcriptional regulators of the yeast cell cycle.

Authors:  Michael A White; Linda Riles; Barak A Cohen
Journal:  Genetics       Date:  2008-11-24       Impact factor: 4.562

Review 5.  Cargo trafficking between endosomes and the trans-Golgi network.

Authors:  Pei Zhi Cheryl Chia; Priscilla Gunn; Paul A Gleeson
Journal:  Histochem Cell Biol       Date:  2013-07-14       Impact factor: 4.304

6.  TLR2 activation enhances HIV nuclear import and infection through T cell activation-independent and -dependent pathways.

Authors:  Jian Ding; Theresa L Chang
Journal:  J Immunol       Date:  2011-12-30       Impact factor: 5.422

7.  Investigation of adaptive responses in bystander cells in 3D cultures containing tritium-labeled and unlabeled normal human fibroblasts.

Authors:  Massimo Pinto; Edouard I Azzam; Roger W Howell
Journal:  Radiat Res       Date:  2010-08       Impact factor: 2.841

8.  Flow cytometric fluorescence pulse width analysis of etoposide-induced nuclear enlargement in HCT116 cells.

Authors:  Kyungsu Kang; Saet Byoul Lee; Ji-Hye Yoo; Chu Won Nho
Journal:  Biotechnol Lett       Date:  2010-04-29       Impact factor: 2.461

9.  Flow cytometric analysis of pollen grains collected from individual bees provides information about pollen load composition and foraging behaviour.

Authors:  Paul Kron; Allison Kwok; Brian C Husband
Journal:  Ann Bot       Date:  2013-11-14       Impact factor: 4.357

10.  alpha-ENaC is a functional element of the hypertonicity-induced cation channel in HepG2 cells and it mediates proliferation.

Authors:  Maryna Bondarava; Tongju Li; Elmar Endl; Frank Wehner
Journal:  Pflugers Arch       Date:  2009-02-25       Impact factor: 3.657

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.