Literature DB >> 11740645

Self-expanding metal stents for endoscopic treatment of esophageal achalasia unresponsive to conventional treatments. Long-term results in eight patients.

G D De Palma1, P lovino, S Masone, M Persico, G Persico.   

Abstract

BACKGROUND AND STUDY AIMS: The successful use of self-expanding metal stents has been demonstrated in the management of malignant esophagocardial strictures. This report assesses the role stents may play in the treatment of esophageal achalasia in selected patients. PATIENTS AND METHODS: Between September 1996 and December 1997, eight patients (two men, six women; average age 67.6 years) underwent insertion of a self-expanding metal stent for management of achalasia. Previous myotomy and/or balloon dilation or injection of botulinum toxin had failed in all patients. Four nitinol coil stents and five covered Ultraflex stents, 10 cm long, were inserted, being passed through the gastroesophageal junction under mild sedation.
RESULTS: Stent placement was successful and uncomplicated in all patients. Early complications were seen in five patients: chest pain (1), gastroesophageal reflux (1), proximal migration (1), and distal migration (2). One patient underwent surgery for stent impaction in the colon. During the follow-up period of 35.5 months, on average (range 29 - 44 months), four patients experienced complications: chest pain (2), reflux esophagitis (1) and stent migration (1).
CONCLUSION: General use of self-expanding metal stents for esophageal achalasia cannot be recommended.

Entities:  

Mesh:

Year:  2001        PMID: 11740645     DOI: 10.1055/s-2001-18933

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  15 in total

1.  Selection and evaluation of three interventional procedures for achalasia based on long-term follow-up.

Authors:  Ying-Sheng Cheng; Ming-Hua Li; Wei-Xiong Chen; Ni-Wei Chen; Qi-Xin Zhuang; Ke-Zhong Shang
Journal:  World J Gastroenterol       Date:  2003-10       Impact factor: 5.742

2.  Temporary self-expanding metallic stents for achalasia: a prospective study with a long-term follow-up.

Authors:  Ying-Sheng Cheng; Fang Ma; Yong-Dong Li; Ni-Wei Chen; Wei-Xiong Chen; Jun-Gong Zhao; Chun-Gen Wu
Journal:  World J Gastroenterol       Date:  2010-10-28       Impact factor: 5.742

3.  Comparison between botulinum injection and removable covered self-expanding metal stents for the treatment of achalasia.

Authors:  Xiao Bo Cai; Yan Miao Dai; Xin Jian Wan; Yue Zeng; Feng Liu; Dong Wang; Hui Zhou
Journal:  Dig Dis Sci       Date:  2013-02-09       Impact factor: 3.199

4.  Endoscopic approach to achalasia.

Authors:  Michaela Müller; Alexander J Eckardt; Till Wehrmann
Journal:  World J Gastrointest Endosc       Date:  2013-08-16

Review 5.  Current approach to the treatment of achalasia.

Authors:  Joseph G Cheatham; Roy K H Wong
Journal:  Curr Gastroenterol Rep       Date:  2011-06

6.  Pseudoachalasia: A peculiar case report and review of the literature.

Authors:  Salvatore Maria Antonio Campo; Angelo Zullo; Chiara Maria Scandavini; Barbara Frezza; Paola Cerro; Genoveffa Balducci
Journal:  World J Gastrointest Endosc       Date:  2013-09-16

7.  Current clinical approach to achalasia.

Authors:  Alexander J Eckardt; Volker F Eckardt
Journal:  World J Gastroenterol       Date:  2009-08-28       Impact factor: 5.742

Review 8.  Achalasia: a review of Western and Iranian experiences.

Authors:  Javad Mikaeli; Farhad Islami; Reza Malekzadeh
Journal:  World J Gastroenterol       Date:  2009-10-28       Impact factor: 5.742

9.  Palliation with oesophageal metal stent of pseudoachalasia from gastric carcinoma at the cardia: a case report.

Authors:  Salvatore Maria Antonio Campo; Roberto Lorenzetti; Marina de Matthaeis; Cesare Hassan; Angelo Zullo; Paola Cerro; Sergio Morini
Journal:  Diagn Ther Endosc       Date:  2009-09-06

10.  Long-term safety and outcome of a temporary self-expanding metallic stent for achalasia: a prospective study with a 13-year single-center experience.

Authors:  Jun-Gong Zhao; Yong-Dong Li; Ying-Sheng Cheng; Ming-Hua Li; Ni-Wei Chen; Wei-Xiong Chen; Ke-Zhong Shang
Journal:  Eur Radiol       Date:  2009-03-19       Impact factor: 5.315