AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively. RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm.
AIM: To compare the efficacy of self-expanding metallic stents (SEMSs) for the long-term clinical treatment of achalasia. METHODS: Ninety achalasic patients were treated with a temporary SEMS with a diameter of 20 mm (n = 30, group A), 25 mm (n = 30, group B) or 30 mm (n = 30, group C). Data on clinical symptoms, complications and treatment outcomes were collected, and follow-up was made at 6 mo and at 1, 3-5, 5-8, 8-10 and > 10 years, postoperatively. RESULTS: Stent placement was successful in all patients. Although chest pain occurrence was high, stent migration was less in group C than in groups A and B. The clinical remission rate at 5-8, 8-10 and > 10 years in group C was higher than that in the other two groups. The treatment failure rate was lower in group C (13%) than in groups A (53%) and B (27%). SEMSs in group C resulted in reduced dysphagia scores and lowered esophageal sphincter pressures, as well as normal levels of barium height and width during all the follow-up time periods. Conversely, these parameters increased over time in groups A and B. The primary patency in group C was longer than in groups A and B. CONCLUSION: A temporary SEMS with a diameter of 30 mm is associated with a superior long-term clinical efficacy in the treatment of achalasia compared with a SEMS with a diameter of 20 mm or 25 mm.
Authors: P Ruiz; J Ortiz de Zárate; S Blanco; J I Varela; A Calderón; F Polo; P Cabezudo; L Marcé; A B Díaz; V Orive Journal: Gastroenterol Hepatol Date: 2006-02 Impact factor: 2.102
Authors: Marisol Luján-Sanchis; Patricia Suárez-Callol; Ana Monzó-Gallego; Inmaculada Bort-Pérez; Lydia Plana-Campos; Luis Ferrer-Barceló; Laura Sanchis-Artero; María Llinares-Lloret; Juan Antonio Tuset-Ruiz; Javier Sempere-Garcia-Argüelles; Pilar Canelles-Gamir; Enrique Medina-Chuliá Journal: World J Gastrointest Endosc Date: 2015-06-10
Authors: Dario Esposito; Francesco Maione; Alessandra D'Alessandro; Giovanni Sarnelli; Giovanni D De Palma Journal: World J Gastrointest Endosc Date: 2016-01-25