Literature DB >> 11737102

Peri-implant health around screw-shaped c.p. titanium machined implants in partially edentulous patients with or without ongoing periodontitis.

M Quirynen1, W Peeters, I Naert, W Coucke, D van Steenberghe.   

Abstract

The relationship between periodontitis and peri-implantitis remains a matter of debate. The present study compared, "within" randomly chosen partially edentulous patients (n=84 subjects, 97 jaws), the marginal bone loss around teeth and implants during 5 years (range 3 to 11 years) following the first year of bone remodelling. The patients had all been rehabilitated by means of screw-shape c.p. titanium implants with a machined surface (Brånemark system). During the 5 years observation interval, periodontal parameters (marginal bone and attachment loss, the latter for teeth only) were collected together with data on confounding factors (smoking, oral hygiene, tooth loss). Marginal bone loss was measured through long-cone intra-oral radiographs. The mean "interval" bone loss was significantly (P=0.0001) higher around teeth (0.48+/-0.95 mm) than around implants (0.09+/-0.28 mm). The corresponding data for the "worst" performing tooth (0.99+/-1.25 mm) and implant (0.19+/-0.32 mm) per subject showed the same tendency. Neither attachment nor bone loss around teeth correlated with marginal bone loss around implants. This study indicated that the rate of bone loss around screw-shape c.p. titanium implants with a machined surface (Brånemark system implants) was not influenced by the progression rate of periodontal destruction around the remaining teeth within the same jaw.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11737102     DOI: 10.1034/j.1600-0501.2001.120606.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Bacterial reduction effect of four different dental lasers on titanium surfaces in vitro.

Authors:  W Patrick Misischia; Pinelopi Xenoudi; Raymond A Yukna; Michael J Schurr
Journal:  Lasers Med Sci       Date:  2021-07-27       Impact factor: 3.161

2.  Impact of Dynamic Loading on the Implant-abutment Interface Using a Gas-enhanced Permeation Test In Vitro.

Authors:  Anas Al-Jadaa; Thomas Attin; Timo Peltomäki; Christian Heumann; Patrick Roger Schmidlin
Journal:  Open Dent J       Date:  2015-03-31

3.  Perioprosthetic and Implant-Supported Rehabilitation of Complex Cases: Clinical Management and Timing Strategy.

Authors:  Luca Landi; Stefano Piccinelli; Roberto Raia; Fabio Marinotti; Paolo Francesco Manicone
Journal:  Case Rep Dent       Date:  2016-11-07

Review 4.  Surgical Regenerative Treatments for Peri-Implantitis: Meta-analysis of Recent Findings in a Systematic Literature Review.

Authors:  Povilas Daugela; Marco Cicciù; Nikola Saulacic
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

Review 5.  Prevalence of Peri-Implantitis in Implants with Turned and Rough Surfaces: a Systematic Review.

Authors:  Nikola Saulacic; Benoit Schaller
Journal:  J Oral Maxillofac Res       Date:  2019-03-31

6.  Increase in receptor activator of nuclear factor κB ligand/osteoprotegerin ratio in peri-implant gingiva exposed to Porphyromonas gingivalis lipopolysaccharide.

Authors:  Takahiro Shuto; Takanori Wachi; Yoshinori Shinohara; Hiroki Nikawa; Seicho Makihira
Journal:  J Dent Sci       Date:  2016-01-06       Impact factor: 2.080

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.