Literature DB >> 11732834

Reliability of hearing thresholds: computer-automated testing with ER-4B Canal Phone earphones.

J A Henry1, C L Flick, A Gilbert, R M Ellingson, S A Fausti.   

Abstract

This study was conducted to document test-retest reliability of hearing thresholds using our computer-automated tinnitus matching technique and Etymotic ER-4B Canal Phone insert earphones. The research design involved repeated threshold measurements both within and between sessions, and testing to evaluate the potential effect of eartip removal and reinsertion. Twenty normal-hearing subjects were evaluated over two testing sessions with the use of a fully automated protocol for determining thresholds with 1-dB precision. Thresholds were first obtained at 0.5-16.0 kHz, in one-third octave frequency steps (16 test frequencies). The octave frequencies were then retested, first without removing the eartips, then after eartip removal and replacement. Responses between sessions differed by an average of 2.5 dB across all 16 test frequencies, and 91.5 percent of the repeated thresholds varied within +/-5 dB (98.1 percent within +/-10 dB). Reliability of within-sessions thresholds was also good, and there was no effect of eartip removal and replacement.

Entities:  

Mesh:

Year:  2001        PMID: 11732834

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  4 in total

1.  Comparison of absolute thresholds derived from an adaptive forced-choice procedure and from reaction probabilities and reaction times in a simple reaction time paradigm.

Authors:  Peter Heil; Heinrich Neubauer; Andreas Tiefenau; Hellmut von Specht
Journal:  J Assoc Res Otolaryngol       Date:  2006-07-06

2.  Methods to eliminate stimulus transduction artifact from insert earphones during electroencephalography.

Authors:  Tom Campbell; Jess R Kerlin; Christopher W Bishop; Lee M Miller
Journal:  Ear Hear       Date:  2012 Jan-Feb       Impact factor: 3.570

3.  Analytical methods for evaluating reliability and validity of mobile audiometry tools.

Authors:  Mona Kelkar; Zhaoxun Hou; Gary C Curhan; Sharon G Curhan; Molin Wang
Journal:  J Acoust Soc Am       Date:  2022-07       Impact factor: 2.482

4.  The new age of play audiometry: prospective validation testing of an iPad-based play audiometer.

Authors:  Jeffrey Yeung; Hedyeh Javidnia; Sophie Heley; Yves Beauregard; Sandra Champagne; Matthew Bromwich
Journal:  J Otolaryngol Head Neck Surg       Date:  2013-03-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.