Literature DB >> 11728750

A comparison of the characteristics of profiles produced with the AMPFlSTR SGM Plus multiplex system for both standard and low copy number (LCN) STR DNA analysis.

J P Whitaker1, E A Cotton, P Gill.   

Abstract

DNA STR profiles have been generated from 1 ng and low copy number (LCN) templates using 28 and 34 cycles of amplification, respectively. Characteristics which facilitate the interpretation of profiles, such as heterozygous balance, allelic dropout and stutter proportions have been quantified. We demonstrate that a reduction in DNA template coupled with an increase in amplification cycle number produces an increased rate of allelic dropout out which can be correlated to the peak areas of those alleles observed. In addition, the LCN conditions increase the degree of peak area asymmetry observed from heterozygotes and the size range of stutters. Analysis of the data allows us to develop sets of guidelines appropriate for interpreting both single and mixed DNA profiles.

Entities:  

Mesh:

Year:  2001        PMID: 11728750     DOI: 10.1016/s0379-0738(01)00557-6

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  29 in total

1.  The effectiveness of protective clothing in the reduction of potential DNA contamination of the scene of crime.

Authors:  G N Rutty; A Hopwood; V Tucker
Journal:  Int J Legal Med       Date:  2003-03-22       Impact factor: 2.686

2.  Forensic identification of urine samples: a comparison between nuclear and mitochondrial DNA markers.

Authors:  V Castella; N Dimo-Simonin; C Brandt-Casadevall; N Robinson; M Saugy; F Taroni; P Mangin
Journal:  Int J Legal Med       Date:  2005-08-30       Impact factor: 2.686

3.  Y-STR analysis of degraded DNA using reduced-size amplicons.

Authors:  Myung Jin Park; Hwan Young Lee; Ukhee Chung; Seung-Chul Kang; Kyoung-Jin Shin
Journal:  Int J Legal Med       Date:  2006-11-15       Impact factor: 2.686

4.  Highly effective DNA extraction method for nuclear short tandem repeat testing of skeletal remains from mass graves.

Authors:  Jon Davoren; Daniel Vanek; Rijad Konjhodzić; John Crews; Edwin Huffine; Thomas J Parsons
Journal:  Croat Med J       Date:  2007-08       Impact factor: 1.351

5.  Validation of testing and interpretation protocols for low template DNA samples using AmpFlSTR Identifiler.

Authors:  Theresa Caragine; Rebecca Mikulasovich; Jeannie Tamariz; Ewelina Bajda; James Sebestyen; Howard Baum; Mechthild Prinz
Journal:  Croat Med J       Date:  2009-06       Impact factor: 1.351

6.  Evaluation of modified Yfiler amplification strategy for compromised samples.

Authors:  Kimberly A Sturk; Michael D Coble; Suzanne M Barritt; Jodi A Irwin
Journal:  Croat Med J       Date:  2009-06       Impact factor: 1.351

7.  An INDEL polymorphism at the X-STR GATA172D05 flanking region.

Authors:  Elzemar Martins Ribeiro Rodrigues; Ney Pereira Carneiro dos Santos; Andrea Kely Campos Ribeiro dos Santos; Anderson Nonato Marinho; Marco Antonio Zago; Iva Gomes; António Amorim; Leonor Gusmão; Sidney Emanuel Batista dos Santos
Journal:  Int J Legal Med       Date:  2008-12-02       Impact factor: 2.686

Review 8.  DNA reviews: low level DNA profiling.

Authors:  Eleanor A M Graham
Journal:  Forensic Sci Med Pathol       Date:  2008-05-14       Impact factor: 2.007

9.  Forensic validation of the PowerPlex® ESI 16 STR Multiplex and comparison of performance with AmpFlSTR® SGM Plus®.

Authors:  Valerie C Tucker; Amanda J Kirkham; Andrew J Hopwood
Journal:  Int J Legal Med       Date:  2011-05-28       Impact factor: 2.686

10.  Magnitude-dependent variation in peak height balance at heterozygous STR loci.

Authors:  Jason R Gilder; Keith Inman; William Shields; Dan E Krane
Journal:  Int J Legal Med       Date:  2010-02-10       Impact factor: 2.686

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.