Literature DB >> 11728701

The effect of setup uncertainty on normal tissue sparing with IMRT for head-and-neck cancer.

M A Manning1, Q Wu, R M Cardinale, R Mohan, A D Lauve, B D Kavanagh, M M Morris, R K Schmidt-Ullrich.   

Abstract

PURPOSE: Intensity-modulated radiotherapy (IMRT) is being evaluated in the management of head-and-neck cancers at several institutions, and a Radiation Therapy Oncology Group study of its utility in parotid sparing is under development. There is an inherent risk that the sharper dose gradients generated by IMRT amplify the potentially detrimental impact of setup uncertainty. The International Commission on Radiation Units and Measurements Report 62 (ICRU-62) defined planning organ-at-risk volume (PRV) to account for positional uncertainties for normal tissues. The purpose of this study is to quantify the dosimetric effect of employing PRV for the parotid gland and to evaluate the use of PRV on normal-tissue sparing in the setting of small clinical setup errors. METHODS AND MATERIALS: The optimized nine-beam IMRT plans for three head-and-neck cancer patients participating in an institutional review board approved parotid-sparing protocol were used as reference plans. A second optimized plan was generated for each patient by adding a PRV of 5 mm for the contralateral parotid gland. The effect of these additions on the quality of the plans was quantified, in terms of both target coverage and normal-tissue sparing. To test the value of PRV in a worst-case scenario, systematic translational setup uncertainties were simulated by shifting the treatment isocenter 5 mm superiorly, inferiorly, left, right, anteriorly, and posteriorly, without altering optimized beam profiles. At each shifted isocenter, dose distributions were recalculated, producing a total of six shifted plans without PRV and six shifted plans with PRV for each patient. The effect of setup uncertainty on parotid sparing and the value of PRV in compensating for the uncertainty were evaluated.
RESULTS: The addition of the PRV and reoptimization did not significantly affect the dose to gross tumor volume, spinal cord, or brainstem. In contrast, without any shift, the PRV did increase parotid sparing and reduce coverage of the nodal region adjacent to the parotid gland. As expected, when the plans were shifted, the greatest increase in contralateral parotid irradiation was noted with shifts toward the contralateral parotid gland. With these shifts, the average volume of contralateral parotid receiving greater than 30 Gy was reduced from 22% to 4% when a PRV was used. This correlated with a reduction in the average normal-tissue complication probability (NTCP) from 22% to 7%.
CONCLUSIONS: The use of PRV may limit the volume of normal tissue structures, such as the parotid gland, exceeding tolerance dose as a result of setup errors. Consequently, it will be important to incorporate the nomenclature of ICRU-62 into the design of future IMRT studies, if the clinical gains of increased normal-tissue sparing are to be realized.

Entities:  

Mesh:

Year:  2001        PMID: 11728701     DOI: 10.1016/s0360-3016(01)01740-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  25 in total

Review 1.  Current progress in adaptive radiation therapy for head and neck cancer.

Authors:  David L Schwartz
Journal:  Curr Oncol Rep       Date:  2012-04       Impact factor: 5.075

2.  Variable planning margin approach to account for locoregional variations in setup uncertainties.

Authors:  Jinzhong Yang; Adam S Garden; Yongbin Zhang; Lifei Zhang; Lei Dong
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

Review 3.  Interobserver variation in parotid gland delineation: a study of its impact on intensity-modulated radiotherapy solutions with a systematic review of the literature.

Authors:  S W Loo; W M C Martin; P Smith; S Cherian; T W Roques
Journal:  Br J Radiol       Date:  2012-08       Impact factor: 3.039

4.  Helical tomotherapy setup variations in canine nasal tumor patients immobilized with a bite block.

Authors:  Lyndsay N Kubicek; Songwon Seo; Richard J Chappell; Robert Jeraj; Lisa J Forrest
Journal:  Vet Radiol Ultrasound       Date:  2012-06-25       Impact factor: 1.363

5.  Dosimetric impact of daily setup variations during treatment of canine nasal tumors using intensity-modulated radiation therapy.

Authors:  Michael A Deveau; Alonso N Gutiérrez; Thomas R Mackie; Wolfgang A Tomé; Lisa J Forrest
Journal:  Vet Radiol Ultrasound       Date:  2010 Jan-Feb       Impact factor: 1.363

6.  Adaptive radiation therapy for head and neck cancer-can an old goal evolve into a new standard?

Authors:  David L Schwartz; Lei Dong
Journal:  J Oncol       Date:  2010-08-18       Impact factor: 4.375

7.  Impact of residual setup error on parotid gland dose in intensity-modulated radiation therapy with or without planning organ-at-risk margin.

Authors:  Anna Delana; Loris Menegotti; Andrea Bolner; Luigi Tomio; Aldo Valentini; Frank Lohr; Valentina Vanoni
Journal:  Strahlenther Onkol       Date:  2009-08-28       Impact factor: 3.621

8.  Robustness quantification methods comparison in volumetric modulated arc therapy to treat head and neck cancer.

Authors:  Wei Liu; Samir H Patel; Jiajian Jason Shen; Yanle Hu; Daniel P Harrington; Xiaoning Ding; Michele Y Halyard; Steven E Schild; William W Wong; Gary A Ezzell; Martin Bues
Journal:  Pract Radiat Oncol       Date:  2016-02-13

9.  Multi-institutional evaluation of MVCT guided patient registration and dosimetric precision in total marrow irradiation: A global health initiative by the international consortium of total marrow irradiation.

Authors:  Darren Zuro; Stefano Vagge; Sara Broggi; Stefano Agostinelli; Yutaka Takahashi; Jamison Brooks; Paulina Leszcynska; An Liu; Claudio Zucchetti; Simonetta Saldi; Chunhui Han; Mauro Cattaneo; Sebastian Giebel; Marc Andre Mahe; James F Sanchez; Parham Alaei; Chiara Anna; Kathryn Dusenbery; Antonio Pierini; Guy Storme; Cynthia Aristei; Jeffrey Y C Wong; Susanta Hui
Journal:  Radiother Oncol       Date:  2019-08-14       Impact factor: 6.280

10.  Dose accumulation to assess the validity of treatment plans with reduced margins in radiotherapy of head and neck cancer.

Authors:  Nicholas J Lowther; Steven H Marsh; Robert J W Louwe
Journal:  Phys Imaging Radiat Oncol       Date:  2020-06-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.