Literature DB >> 11727016

Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies.

K E Applegate1, J T Dardinger, M L Lieber, B R Herts, W J Davros, N A Obuchowski, A Maneker.   

Abstract

BACKGROUND: Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB.
OBJECTIVE: To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique.
MATERIALS AND METHODS: Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system.
RESULTS: The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity < 35 %). The optimal technique for visualizing the LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans.
CONCLUSION: Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized.

Entities:  

Mesh:

Year:  2001        PMID: 11727016     DOI: 10.1007/s002470100001

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  8 in total

Review 1.  Multi-detector computed tomography imaging of large airway pathology: A pictorial review.

Authors:  Tejeshwar Singh Jugpal; Anju Garg; Gulshan Rai Sethi; Mradul Kumar Daga; Jyoti Kumar
Journal:  World J Radiol       Date:  2015-12-28

2.  Three-dimensional CT with virtual bronchoscopy: a useful modality for bronchial foreign bodies in pediatric patients.

Authors:  Soo Yeon Jung; So Young Pae; Sung Min Chung; Han Su Kim
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-03-16       Impact factor: 2.503

3.  Clinical application of surface projection in the localization of metal foreign bodies using computed tomography scan.

Authors:  Hexiang Qian; Changwen Shi; Guangfu Xing
Journal:  Br J Radiol       Date:  2015-07-21       Impact factor: 3.039

4.  CT evaluation of airway foreign bodies in children: emphasis on the delayed diagnosis and differentiation from airway mucus plugs.

Authors:  Won Sun Hong; Soo Ah Im; Hyo Lim Kim; Jong-Seo Yoon
Journal:  Jpn J Radiol       Date:  2012-10-18       Impact factor: 2.374

5.  CT virtual bronchoscopy: new non invasive tool in pediatric patients with foreign body aspiration.

Authors:  Kushaljit Singh Sodhi; Akshay Kumar Saxena; Meenu Singh; K L N Rao; N Khandelwal
Journal:  Indian J Pediatr       Date:  2008-06-08       Impact factor: 1.967

6.  Three-dimensional computed tomography for detection of tracheobronchial foreign body aspiration in children.

Authors:  H-J Huang; H-Y Fang; H-C Chen; C-Y Wu; C-Y Cheng; C-L Chang
Journal:  Pediatr Surg Int       Date:  2007-11-27       Impact factor: 1.827

Review 7.  Clinical presentation, diagnosis and management of aerodigestive tract foreign bodies in the paediatric population: Part 2.

Authors:  Rishi P Mathew; Teresa I-Han Liang; Ahamed Kabeer; Vimal Patel; Gavin Low
Journal:  SA J Radiol       Date:  2021-03-23

Review 8.  Multidetector row CT for imaging the paediatric tracheobronchial tree.

Authors:  Georgia Papaioannou; Carolyn Young; Catherine M Owens
Journal:  Pediatr Radiol       Date:  2007-04-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.