Application of indirect flow rate measurement using motor driving signals to a centrifugal blood pump with an integrated motor.

T Tsukiya1, Y Taenaka, T Nishinaka, M Oshikawa, H Ohnishi, E Tatsumi, H Takano, Y Konishi, K Ito, M Shimada.   

Abstract

The method of measuring the flow rate of a centrifugal blood pump from the input electric power, which will be indispensable for the long-term use of such devices, was developed and was applied to the direct-driven centrifugal blood pump that has been developed by our research group. The accuracy was evaluated in a chronic animal experiment using an adult goat. The results demonstrated that this method carries the sufficient potential of the instantaneous monitoring method, but errors due to electromagnetic and mechanical losses were not determined always precisely. The detection of adverse phenomena such as the obstruction of the inlet cannula was also possible from the estimated value of the flow rate and its waveform pattern.

Entities:  

Mesh:

Year:  2001        PMID: 11722344     DOI: 10.1046/j.1525-1594.2001.06858.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

1.  Sensorless cardiac phase detection for synchronized control of ventricular assist devices using nonlinear kernel regression model.

Authors:  Yoshihiro Hirohashi; Akira Tanaka; Makoto Yoshizawa; Norihiro Sugita; Makoto Abe; Tsuyoshi Kato; Yasuyuki Shiraishi; Hidekazu Miura; Tomoyuki Yambe
Journal:  J Artif Organs       Date:  2016-01-13       Impact factor: 1.731

2.  Development of a miniature motor-driven pulsatile LVAD driven by a fuzzy controller.

Authors:  Eiji Okamoto; Tsutomu Makino; Shuji Tanaka; Takahiko Yasuda; Yuta Akasaka; Makiko Tani; Yusuke Inoue; Ayumu Mitoh; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2007-09-20       Impact factor: 1.731

3.  Circadian variation of motor current observed in fixed rotation speed continuous-flow left ventricular assist device support.

Authors:  Kenji Suzuki; Tomohiro Nishinaka; Takuma Miyamoto; Yuki Ichihara; Kenji Yamazaki
Journal:  J Artif Organs       Date:  2014-04-09       Impact factor: 1.731

4.  Beneficial aspects of real time flow measurements for the management of acute right ventricular heart failure following continuous flow ventricular assist device implantation.

Authors:  Sotirios Spiliopoulos; Dilek Guersoy; Reiner Koerfer; Gero Tenderich
Journal:  J Cardiothorac Surg       Date:  2012-11-12       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.