BACKGROUND: L-pipecolic acid (L-PA), an important biochemical marker for the diagnosis of peroxisomal disorders, is usually determined as the racemate. We developed a chiral liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of L-PA in plasma. METHODS: We used a narrow bore chiral macrocyclic glycopeptide teicoplanin column for the enantioseparation of D-pipecolic acid (D-PA) and L-PA and interfaced the column directly to the electrospray source of a tandem mass spectrometer. We used phenylalanine-d5 as internal standard added to 50 microL of plasma followed by deproteinization, evaporation, and injection. The analysis was performed in the selected-reaction monitoring mode using two transitions: m/z 130-->m/z 84 for PA, and m/z 171-->m/z 125 for phenylalanine-d5. L-PA eluted at 7 min, and D-PA eluted at 11.7 min, whereas phenylalanine-d5 eluted at 6 min. The turnaround time for the assay was 20 min. RESULTS: Linear calibration curves were obtained in the range of 0.5-80 micromol/L. At a plasma concentration of 1.0 micromol/L, the signal-to-noise ratio was 50:1. The intra- and interassay variations were 3.1-7.9% and 5.7-13%, respectively, at concentrations of 1-50 micromol/L. Mean recoveries of L-PA added to plasma were 95% (5 micromol/L) and 102% (50 micromol/L). The method clearly distinguished between healthy individuals and peroxisomal disease patients. CONCLUSIONS: The novel LC-MS/MS method is simple, rapid, and stereoselective, and uses only 50 microL of plasma, no derivatizing reagents, and a commercially available internal standard. Sample preparation is not complex and is faster than for all other methods.
BACKGROUND:L-pipecolic acid (L-PA), an important biochemical marker for the diagnosis of peroxisomal disorders, is usually determined as the racemate. We developed a chiral liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the analysis of L-PA in plasma. METHODS: We used a narrow bore chiral macrocyclic glycopeptideteicoplanin column for the enantioseparation of D-pipecolic acid (D-PA) and L-PA and interfaced the column directly to the electrospray source of a tandem mass spectrometer. We used phenylalanine-d5 as internal standard added to 50 microL of plasma followed by deproteinization, evaporation, and injection. The analysis was performed in the selected-reaction monitoring mode using two transitions: m/z 130-->m/z 84 for PA, and m/z 171-->m/z 125 for phenylalanine-d5. L-PA eluted at 7 min, and D-PA eluted at 11.7 min, whereas phenylalanine-d5 eluted at 6 min. The turnaround time for the assay was 20 min. RESULTS: Linear calibration curves were obtained in the range of 0.5-80 micromol/L. At a plasma concentration of 1.0 micromol/L, the signal-to-noise ratio was 50:1. The intra- and interassay variations were 3.1-7.9% and 5.7-13%, respectively, at concentrations of 1-50 micromol/L. Mean recoveries of L-PA added to plasma were 95% (5 micromol/L) and 102% (50 micromol/L). The method clearly distinguished between healthy individuals and peroxisomal diseasepatients. CONCLUSIONS: The novel LC-MS/MS method is simple, rapid, and stereoselective, and uses only 50 microL of plasma, no derivatizing reagents, and a commercially available internal standard. Sample preparation is not complex and is faster than for all other methods.
Authors: Andrew D Patterson; Jessica A Bonzo; Fei Li; Kristopher W Krausz; Gabriel S Eichler; Sadaf Aslam; Xenia Tigno; John N Weinstein; Barbara C Hansen; Jeffrey R Idle; Frank J Gonzalez Journal: J Biol Chem Date: 2011-04-12 Impact factor: 5.157
Authors: Femke C C Klouwer; Sacha Ferdinandusse; Henk van Lenthe; Wim Kulik; Ronald J A Wanders; Bwee Tien Poll-The; Hans R Waterham; Frédéric M Vaz Journal: J Inherit Metab Dis Date: 2017-07-04 Impact factor: 4.982
Authors: Reda F A Abdelhameed; Asmaa I Ali; Sameh S Elhady; Hend E Abo Mansour; Eman T Mehanna; Sarah M Mosaad; Salma A Ibrahim; Rawan H Hareeri; Jihan M Badr; Nermeen A Eltahawy Journal: Plants (Basel) Date: 2022-09-03
Authors: Kevin Berendse; Femke C C Klouwer; Bart G P Koot; Elles M Kemper; Sacha Ferdinandusse; Kiran V K Koelfat; Martin Lenicek; Frank G Schaap; Hans R Waterham; Frédéric M Vaz; Marc Engelen; Peter L M Jansen; Ronald J A Wanders; Bwee Tien Poll-The Journal: J Inherit Metab Dis Date: 2016-07-28 Impact factor: 4.982
Authors: Kevin Berendse; Marc Engelen; Sacha Ferdinandusse; Charles B L M Majoie; Hans R Waterham; Frédéric M Vaz; Johannes H T M Koelman; Peter G Barth; Ronald J A Wanders; Bwee Tien Poll-The Journal: J Inherit Metab Dis Date: 2015-08-19 Impact factor: 4.982