Literature DB >> 11716329

MR angiography of the hand arteries.

U Krause1, T Pabst, W Kenn, G Wittenberg, D Hahn.   

Abstract

The aim of this study was to optimize different magnetic resonance angiography (MRA) techniques and to evaluate MRA of the hand arteries compared to intraarterial digital subtraction angiography (IA-DSA). The MRA examinations were performed on a 1.5-T system equipped with a flexible surface coil. The protocol contained time-of-flight (TOF), rephased/dephased (Re/De), and contrast enhanced (CE) techniques. Maximum intensity projection (MIP) was used for postprocessing. The IA-DSA procedure was performed as pharmaco-angiography (after intraarterial injection of a vasodilatator) via a transbrachial approach. Nine patients suffering from peripheral vascular disease were examined with IA-DSA, TOF-MRA, and Re/De-MRA; six patients were examined with CE-MRA and IA-DSA. Best overall image quality was attained with IA-DSA, followed by TOF-MRA, Re/De-MRA, and CE-MRA. Selective arterial visualization of digital arteries was possible with IA-DSA and TOF-MRA. Rephased/dephased MRA showed venous overlay. Contrast-enhanced MRA was limited by inconstant quality of bolus timing. Appropriate arterial bolus timing was achieved in four of six patients; one examination showed venous overlay, one examination incomplete arterial enhancement. Time-of-flight MRA detected 96% of the digital artery segments that were identified with IA-DSA and revealed 34 segments that were failed on IA-DSA. Rephased/dephased MRA and CE-MRA were inferior to IA-DSA and TOF-MRA regarding detection of digital arteries. Magnetic resonance angiography with optimized protocols is a noninvasive procedure to visualize hand arteries in patients with ischemic disease. With TOF-MRA it is possible to detect angiographically occluded arterial segments of digital arteries.

Entities:  

Mesh:

Year:  2001        PMID: 11716329     DOI: 10.1177/000331970105201106

Source DB:  PubMed          Journal:  Angiology        ISSN: 0003-3197            Impact factor:   3.619


  5 in total

1.  Three-dimensional electrocardiographically gated variable flip angle FSE imaging for MR angiography of the hands at 3.0 T: initial experience.

Authors:  Ruth P Lim; Pippa Storey; Iliyana P Atanasova; Jian Xu; Elizabeth M Hecht; James S Babb; David R Stoffel; Hugo Chang; Kellyanne McGorty; Qun Chen; Henry Rusinek; H Michael Belmont; Vivian S Lee
Journal:  Radiology       Date:  2009-06-30       Impact factor: 11.105

2.  Directional Doppler and angiography in the assessment of the postoperative function of the microvascular anastomoses: a comparative study.

Authors:  S K Vilkki; A Metsa; S Seppänen
Journal:  J Hand Microsurg       Date:  2009-07-10

3.  Noncontrast magnetic resonance angiography of the hand: improved arterial conspicuity by multidirectional flow-sensitive dephasing magnetization preparation in 3D balanced steady-state free precession imaging.

Authors:  Zhaoyang Fan; Philip A Hodnett; Amir H Davarpanah; Timothy G Scanlon; John J Sheehan; John Varga; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2011-08       Impact factor: 6.016

4.  High-resolution, non-contrast-enhanced magnetic resonance angiography of the wrist, hand and digital arteries using optimized implementation of Cartesian quiescent interval slice selective (QISS) at 1.5 T.

Authors:  Mona Salehi Ravesh; Annett Lebenatus; Alexandra Bonietzki; Johannes Hensler; Ioannis Koktzoglou; Robert R Edelman; Joachim Graessner; Olav Jansen; Marcus Both
Journal:  Magn Reson Imaging       Date:  2021-02-11       Impact factor: 2.546

5.  Hand vasospasm, mimicking acute upper limb ischaemia.

Authors:  Keisuke Nakabayashi; Hiroshi Ando
Journal:  BMJ Case Rep       Date:  2020-07-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.