Literature DB >> 11707718

Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation.

T H Lim1, J G Kim, A Fujiwara, T T Yoon, S C Lee, J W Ha, H S An.   

Abstract

STUDY
DESIGN: Flexibility tests and finite element analyses were performed for the biomechanical evaluation of diagonal transfixation in pedicle screw instrumentation.
OBJECTIVE: To assess the biomechanical advantages of diagonal transfixation compared with conventional horizontal transfixation. SUMMARY AND BACKGROUND DATA: A few pedicle screw instrumentation systems allow the use of cross-links in the diagonal direction. Such a diagonal transfixation is anticipated to improve the surgical construct stability, but its biomechanical qualities have not been completely evaluated.
METHODS: Flexibility tests were performed on 10 calf lumbar spines (L2-L5). Specimens were subjected to pure moments up to 8.2 Nm in flexion, extension, lateral bending, and extension while the resulting movements of L3 and L4 were measured by a three-dimensional motion analysis system. The tested cases included (1) intact, (2) pedicle screw fixation without transfixation after total removal of the L3-L4 disc, (3) pedicle screw fixation with diagonal transfixation, and (4) pedicle screw fixation with horizontal transfixation. Three-dimensional finite element models of the tested surgical constructs were also developed by use of three-dimensional beam elements to investigate the effect of diagonal transfixation and horizontal transfixation on the construct stability and the corresponding stress changes in the screws.
RESULTS: When compared with no transfixation, horizontal transfixation significantly improved the lateral bending and axial rotation stability by 15.7% and 13.9%, respectively, but there was no improvement of stability in flexion and extension. By contrast, diagonal transfixation significantly improved the flexion and extension stability by 12% and 10.7%, respectively, but not the lateral bending and axial rotation stability in comparison with no transfixation. Comparison between horizontal transfixation and diagonal transfixation showed that the stabilizing effect of diagonal transfixation was greater in flexion and extension (13% and 11%, P < 0.01) than that of horizontal transfixation but smaller in lateral bending (11%, P < 0.05) and axial rotation (6.6%, P > 0.1). Finite element model predictions of the motion changes were similar to the changes observed in flexibility tests. In horizontal transfixation, the load changes, compared with no transfixion, were a 0.02% increase in flexion-extension, a 27.5% increase in lateral bending, and a 58% decrease in axial rotation, and the magnitudes of the moments applied on both the right and left pedicle screws were identical. However, when diagonal transfixation was achieved by connecting the left superior screw and the right inferior screw, the loads in the left screw were increased by 11.5% in flexion-extension, 43.6% in lateral bending, and 7.9% in axial rotation, whereas the loads in the right screw were decreased by 10.9% in flexion-extension, increased by 0.06% in lateral bending, and decreased by 18.1% in axial rotation.
CONCLUSIONS: The results of this study showed that diagonal transfixation provides more rigid fixation in flexion and extension but less in lateral bending and axial rotation in comparison with horizontal transfixation. Furthermore, greater stresses in the pedicle screws were predicted in the diagonal transfixation model. These limitations of diagonal transfixation should be considered carefully for clinical application.

Entities:  

Mesh:

Year:  2001        PMID: 11707718     DOI: 10.1097/00007632-200111150-00020

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  7 in total

1.  Effect of pilot hole on biomechanical and in vivo pedicle screw-bone interface.

Authors:  Patrícia Silva; Rodrigo César Rosa; Antonio Carlos Shimano; Helton L A Defino
Journal:  Eur Spine J       Date:  2013-05-08       Impact factor: 3.134

Review 2.  Cross-links in posterior pedicle screw-rod instrumentation of the spine: a systematic review on mechanical, biomechanical, numerical and clinical studies.

Authors:  Frédéric Cornaz; Jonas Widmer; Jess Gerrit Snedeker; José Miguel Spirig; Mazda Farshad
Journal:  Eur Spine J       Date:  2020-10-03       Impact factor: 3.134

3.  Are the spines of calf, pig and sheep suitable models for pre-clinical implant tests?

Authors:  A Kettler; L Liakos; B Haegele; H-J Wilke
Journal:  Eur Spine J       Date:  2007-08-25       Impact factor: 3.134

4.  [Biomechanical study of a ventral stand-alone cage for the lumbar spine with and without additional posterior fixation].

Authors:  U Vieweg; M Liner; M Lühn; A Neurauter; M Blauth; W Schmoelz
Journal:  Orthopade       Date:  2008-06       Impact factor: 1.004

5.  Posterior spinal instrumentation and decompression with or without cross-link?

Authors:  Marco D Burkhard; Frédéric Cornaz; José Miguel Spirig; Florian Wanivenhaus; Rafael Loucas; Marie-Rosa Fasser; Jonas Widmer; Mazda Farshad
Journal:  N Am Spine Soc J       Date:  2021-11-17

6.  Biomechanical Evaluation of the Cross-link Usage and Position in the Single and Multiple Segment Posterior Lumbar Interbody Fusion.

Authors:  Lin Han; Haisong Yang; Yongheng Li; Zhiyong Li; Hongdao Ma; Chenfeng Wang; Jincan Yuan; Luyu Zheng; Qiang Chen; Xuhua Lu
Journal:  Orthop Surg       Date:  2022-09-14       Impact factor: 2.279

7.  Development and kinematic verification of a finite element model for the lumbar spine: application to disc degeneration.

Authors:  Elena Ibarz; Antonio Herrera; Yolanda Más; Javier Rodríguez-Vela; José Cegoñino; Sergio Puértolas; Luis Gracia
Journal:  Biomed Res Int       Date:  2012-12-05       Impact factor: 3.411

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.