Literature DB >> 11698825

A multicenter study of the Vibrant Soundbridge middle ear implant: early clinical results and experience.

B Fraysse1, J P Lavieille, S Schmerber, V Enée, E Truy, C Vincent, F M Vaneecloo, O Sterkers.   

Abstract

OBJECTIVE: The Vibrant Soundbridge (VBS; Symphonix Devices, Inc., San Jose, CA, U.S.A.) is an active, semi-implantable, middle ear hearing device that directly drives the ossicular chain and is used in the treatment of patients with mild to severe sensorineural hearing loss. The benefits of the VBS and the effects of surgery were examined and compared with the preoperative aided condition in 25 patients with implants. STUDY
DESIGN: Single-subject repeated-measures evaluations were performed with each patient acting as his or her own control. Objective audiologic measures and subjective questionnaires also were used.
SETTING: Five tertiary referral and teaching hospitals.
SUBJECTS: Adult patients had bilateral sensorineural hearing loss (average hearing loss, 56 dB; range, 33-80 dB). Twenty-one patients had worn a conventional hearing aid before surgery (11 binaurally, 10 monaurally). Four patients had not used a conventional hearing aid before surgery. INTERVENTION: Rehabilitative.
RESULTS: No significant change in residual hearing after surgery was observed. Functional gain was significantly superior with the VBS. No significant differences were observed for aided speech recognition in quiet. A significant improvement in communication in various listening conditions was reported with the VBS as compared with conventional hearing aids.
CONCLUSION: The VBS surgical implantation procedure does not affect the residual hearing level in the implanted ear, nor does it present any unacceptable risk. Measurable benefit from the VBS in comparison with conventional amplification was demonstrated with regard to the provision of superior usable amplification and greater ease in communication in daily listening environments for the majority of patients.

Entities:  

Mesh:

Year:  2001        PMID: 11698825     DOI: 10.1097/00129492-200111000-00041

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  16 in total

1.  A longitudinal study on postoperative hearing thresholds with the Vibrant Soundbridge device.

Authors:  C Vincent; B Fraysse; J-P Lavieille; E Truy; O Sterkers; F-M Vaneecloo
Journal:  Eur Arch Otorhinolaryngol       Date:  2004-10       Impact factor: 2.503

Review 2.  [Semi-implantable hearing aids for sensorineural hearing loss and combined hearing loss: experiences at the German Armed Forces Hospital in Ulm].

Authors:  M Tisch; H Maier
Journal:  HNO       Date:  2009-03       Impact factor: 1.284

3.  The vibrant® soundbridge™.

Authors:  Deborah Arthur
Journal:  Trends Amplif       Date:  2002-06

4.  Minimal Reporting Standards for Active Middle Ear Hearing Implants.

Authors:  Hannes Maier; Uwe Baumann; Wolf-Dieter Baumgartner; Dirk Beutner; Marco D Caversaccio; Thomas Keintzel; Martin Kompis; Thomas Lenarz; Astrid Magele; Torsten Mewes; Alexander Müller; Tobias Rader; Torsten Rahne; Sebastian P Schraven; Burkard Schwab; Georg Mathias Sprinzl; Bernd Strauchmann; Ingo Todt; Thomas Wesarg; Barbara Wollenberg; Stefan K Plontke
Journal:  Audiol Neurootol       Date:  2018-09-07       Impact factor: 1.854

5.  Vibrant SoundBridge application to middle ear windows versus conventional hearing aids: a comparative study based on international outcome inventory for hearing aids.

Authors:  Ahmet Atas; Hakan Tutar; Bulent Gunduz; Yıldırım A Bayazıt
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-02-12       Impact factor: 2.503

Review 6.  [The Vibrant Soundbridge as an active implant in middle ear surgery].

Authors:  T Beleites; M Bornitz; M Neudert; T Zahnert
Journal:  HNO       Date:  2014-07       Impact factor: 1.284

Review 7.  Systematic review to evaluate the safety, efficacy and economical outcomes of the Vibrant Soundbridge for the treatment of sensorineural hearing loss.

Authors:  Karl-Ludwig Bruchhage; Anke Leichtle; Rainer Schönweiler; Ingo Todt; Wolf-Dieter Baumgartner; Henning Frenzel; Barbara Wollenberg
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-10-31       Impact factor: 2.503

8.  A tri-coil bellows-type round window transducer with improved frequency characteristics for middle-ear implants.

Authors:  Dong Ho Shin; Ki Woong Seong; Sunil Puria; Kyu-Yup Lee; Jin-Ho Cho
Journal:  Hear Res       Date:  2016-09-02       Impact factor: 3.208

9.  Vibrant Soundbridge middle ear implantations: experience at National University Hospital Singapore.

Authors:  Lynne Hsueh Yee Lim; Jocelynne Del Prado; Ling Xiang; Abdul Rahman Bin Yusof; Jenny Hooi Yin Loo
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-03-28       Impact factor: 2.503

10.  Long-term functional outcome and satisfaction of patients with an active middle ear implant for sensorineural hearing loss compared to a matched population with conventional hearing aids.

Authors:  Friedrich Ihler; Julian Bewarder; Jenny Blum; Christoph Matthias; Martin Canis
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-11-19       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.