Literature DB >> 11693758

Detection and prediction of acute heart transplant rejection with the myocardial T2 determination provided by a black-blood magnetic resonance imaging sequence.

P Y Marie1, M Angioï, J P Carteaux, J M Escanye, S Mattei, K Tzvetanov, O Claudon, N Hassan, N Danchin, G Karcher, A Bertrand, P M Walker, J P Villemot.   

Abstract

OBJECTIVES: This study aimed to determine whether the myocardial T2 relaxation time, determined using a black-blood magnetic resonance imaging (MRI) sequence, could predict acute heart transplant rejection.
BACKGROUND: The use of black-blood MRI sequences allows suppression of the confusing influence of blood signal when myocardial T2 is calculated to detect myocardial edema.
METHODS: A total of 123 investigations, including cardiac MRI and myocardial biopsy, were performed 8 +/- 11 months after heart transplantation. Myocardial T2 was determined using an original inversion-recovery/spin-echo sequence.
RESULTS: A higher than normal T2 (> or = 56 ms) allowed an accurate detection of the moderate acute rejections evidenced at baseline biopsy (> or = International Society for Heart and Lung Transplantation grade 2): sensitivity, 89% and specificity, 70% (p < 0.0001). T2 was increased in grade 2 (n = 11) compared with grade 0 (n = 49, p < 0.05), grade 1A (n = 34, p < 0.05) and grade 1B (n = 21, p < 0.05); T2 was further increased in grade 3 (n = 8) compared with grade 2 (p < 0.05). In addition, in patients without rejection equal to or greater than grade 2 at baseline, a T2 higher than normal (> or = 56 ms) was correlated with the subsequent occurrence of equal or greater than grade 2 rejection within the next three months: sensitivity 63% (12/19) and specificity 78% (64/82) (p = 0.001).
CONCLUSIONS: Myocardial T2 determined using a black-blood MRI sequence, is sufficiently sensitive to identify most of the moderate acute rejections documented with biopsy at the same time, but is also a predictor of the subsequent occurrence of such biopsy-defined rejections.

Entities:  

Mesh:

Year:  2001        PMID: 11693758     DOI: 10.1016/s0735-1097(00)01196-7

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  46 in total

Review 1.  Utility of T2-weighted short-tau inversion recovery (STIR) sequences in cardiac MRI: an overview of clinical applications in ischaemic and non-ischaemic heart disease.

Authors:  M Francone; I Carbone; L Agati; C Bucciarelli Ducci; M Mangia; I Iacucci; C Catalano; R Passariello
Journal:  Radiol Med       Date:  2010-10-06       Impact factor: 3.469

2.  Motion correction of multi-contrast images applied to T₁and T₂quantification in cardiac MRI.

Authors:  Anne Menini; Glenn S Slavin; Jeffrey A Stainsby; Pauline Ferry; Jacques Felblinger; Freddy Odille
Journal:  MAGMA       Date:  2015-02       Impact factor: 2.310

3.  Evaluation of perfusion and viability in hypothermic non-beating isolated porcine hearts using cardiac MRI.

Authors:  Andrew L Rivard; Cory M Swingen; Robert P Gallegos; Daniel L Gatlin; Michael Jerosch-Herold; Ranjit John; Richard W Bianco
Journal:  Int J Cardiovasc Imaging       Date:  2005-10-25       Impact factor: 2.357

4.  A comparison of myocardial perfusion and rejection in cardiac transplant patients.

Authors:  Andrew L Rivard; Cory M Swingen; Donnevan Blake; Andrea S Huang; Pooja Kanth; Grete F Thomsen; Erin J Cordova; Leslie W Miller; Richard W Bianco; Norbert Wilke
Journal:  Int J Cardiovasc Imaging       Date:  2007-01-06       Impact factor: 2.357

5.  Prevalence of different forms of infarct-atypical late gadolinium enhancement in patients early and late after heart transplantation.

Authors:  M F Braggion-Santos; F Andre; D Lossnitzer; E Hofmann; J Simpfendörfer; A Dösch; H A Katus; H Steen
Journal:  Clin Res Cardiol       Date:  2014-01       Impact factor: 5.460

6.  Simultaneous multislice cardiac magnetic resonance fingerprinting using low rank reconstruction.

Authors:  Jesse I Hamilton; Yun Jiang; Dan Ma; Yong Chen; Wei-Ching Lo; Mark Griswold; Nicole Seiberlich
Journal:  NMR Biomed       Date:  2018-12-18       Impact factor: 4.044

7.  Diagnostic performance of cardiac magnetic resonance for the detection of acute cardiac allograft rejection: a systematic review and meta-analysis.

Authors:  Wei Lu; Jun Zheng; Xu-Dong Pan; Ming-Duo Zhang; Tie-Yuan Zhu; Bin Li; Li-Zhong Sun
Journal:  J Thorac Dis       Date:  2015-03       Impact factor: 2.895

8.  Cardiac Structure-Function MRI in Patients After Heart Transplantation.

Authors:  Ryan S Dolan; Amir A Rahsepar; Julie Blaisdell; Kai Lin; Kenichiro Suwa; Kambiz Ghafourian; Jane E Wilcox; Sadiya S Khan; Esther E Vorovich; Jonathan D Rich; Allen S Anderson; Clyde W Yancy; Jeremy D Collins; Michael Markl; James C Carr
Journal:  J Magn Reson Imaging       Date:  2018-08-24       Impact factor: 4.813

Review 9.  T2-weighted cardiovascular magnetic resonance in acute cardiac disease.

Authors:  Ingo Eitel; Matthias G Friedrich
Journal:  J Cardiovasc Magn Reson       Date:  2011-02-18       Impact factor: 5.364

Review 10.  Cardiovascular magnetic resonance in the diagnosis of acute heart transplant rejection: a review.

Authors:  Craig R Butler; Richard Thompson; Mark Haykowsky; Mustafa Toma; Ian Paterson
Journal:  J Cardiovasc Magn Reson       Date:  2009-03-12       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.