Literature DB >> 11688664

Quality of vision with presbyopic contact lens correction: subjective and light sensitivity rating.

S Alongi1, M Rolando, G Corallo, C Siniscalchi, M Monaco, S Saccà, G Verrastro, S Menoni, G B Ravera, G Calabria.   

Abstract

PURPOSE: To quantify the quality of vision achieved with multifocal and bifocal contact lenses.
METHODS: We analyzed differential light sensitivity by computerized automatic perimetry in 21 patients wearing monofocal soft contact lenses (group 1, controls) and multifocal and bifocal contact lenses (groups 2 and 3, respectively). Seven patients each were fitted with multifocal or bifocal contact lenses; seven patients were without contact lenses (without correction for testing the visual periphery and with near-vision correction using monofocal contact lens for testing the central 30 degrees of vision). The type of correction was randomly changed in a crossover fashion so that each eye was examined at different times with different corrections. Humphrey 640 VFA computerized automated perimetry was used to test visual fields at baseline, 45 days, and 3, 4.5, and 6 months.
RESULTS: A statistically significant difference was found between the global sensitivities (GS) of the central visual field in patients with near-vision monofocal contact lenses and with bifocal contact lenses (P=0.0273) and between the GS of the central visual fields with multifocal contact lenses and with bifocal contact lenses (P=0.0261). In both cases, the GS were significantly reduced with bifocal contact lenses (total GS: group 1, 11256 dB (Decibels); group 2, 11154 dB; group 3, 10679 dB).
CONCLUSIONS: The results indicate that there is reduced differential light sensitivity in the central 30 deg of the visual field with bifocal contact lenses compared with multifocal contact lenses and monofocal contact lenses (controls).

Entities:  

Mesh:

Year:  2001        PMID: 11688664     DOI: 10.1007/s004170100316

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  2 in total

1.  Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

Authors:  Kazunori Hirasawa; Hikaru Ito; Yukari Ohori; Yui Takano; Nobuyuki Shoji
Journal:  Int J Ophthalmol       Date:  2017-10-18       Impact factor: 1.779

Review 2.  [Compensation for presbyopia using contact lenses].

Authors:  G Bischoff
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.