OBJECTIVE: To compare a second-generation thoracic electrical bioimpedance (TEB) hemodynamic monitoring system with the clinically used pulmonary artery catheter thermodilution (TD-PAC) system. DESIGN: Blinded, simultaneous measurements at specified key time points during surgery. SETTING: University teaching hospital cardiac surgical operating rooms. PARTICIPANTS: Forty-seven patients undergoing primary elective coronary artery bypass surgery. INTERVENTIONS: Timed cardiac output measurements by thermodilution and continuous monitoring of bioimpedance were performed. MEASUREMENTS AND MAIN RESULTS: Cardiac index (TEB and TD-PAC) and other hemodynamic parameters were measured at 4 time points: (1) after anesthesia induction, (2) with the mediastinum open, (3) immediately after cardiopulmonary bypass, and (4) at the end of the case. Pearson's correlation and Bland-Altman analysis were carried out. Cardiac index by TEB and TD-PAC had an overall correlation of r = 0.71 (p < 0.0001). The Bland-Altman statistics showed a mean difference of -0.28 L/min/m2 and precision of 0.67 L/min/m2. The best correlation was at time 1, and the lowest correlation was at time 4. Mediastinal opening and cardiopulmonary bypass had little or no effect on the correlation between technologies. CONCLUSION: TEB reporting of cardiac index during coronary artery surgery generally agreed with TD-PAC cardiac index except at the end of the case (time 4). Copyright 2001 by W.B. Saunders Company
OBJECTIVE: To compare a second-generation thoracic electrical bioimpedance (TEB) hemodynamic monitoring system with the clinically used pulmonary artery catheter thermodilution (TD-PAC) system. DESIGN: Blinded, simultaneous measurements at specified key time points during surgery. SETTING: University teaching hospital cardiac surgical operating rooms. PARTICIPANTS: Forty-seven patients undergoing primary elective coronary artery bypass surgery. INTERVENTIONS: Timed cardiac output measurements by thermodilution and continuous monitoring of bioimpedance were performed. MEASUREMENTS AND MAIN RESULTS: Cardiac index (TEB and TD-PAC) and other hemodynamic parameters were measured at 4 time points: (1) after anesthesia induction, (2) with the mediastinum open, (3) immediately after cardiopulmonary bypass, and (4) at the end of the case. Pearson's correlation and Bland-Altman analysis were carried out. Cardiac index by TEB and TD-PAC had an overall correlation of r = 0.71 (p < 0.0001). The Bland-Altman statistics showed a mean difference of -0.28 L/min/m2 and precision of 0.67 L/min/m2. The best correlation was at time 1, and the lowest correlation was at time 4. Mediastinal opening and cardiopulmonary bypass had little or no effect on the correlation between technologies. CONCLUSION: TEB reporting of cardiac index during coronary artery surgery generally agreed with TD-PAC cardiac index except at the end of the case (time 4). Copyright 2001 by W.B. Saunders Company
Authors: Igor Barjaktarevic; William E Toppen; Scott Hu; Elizabeth Aquije Montoya; Stephanie Ong; Russell Buhr; Ian J David; Tisha Wang; Talayeh Rezayat; Steven Y Chang; David Elashoff; Daniela Markovic; David Berlin; Maxime Cannesson Journal: Crit Care Med Date: 2018-11 Impact factor: 7.598
Authors: Pierre Squara; Dominique Denjean; Philippe Estagnasie; Alain Brusset; Jean Claude Dib; Claude Dubois Journal: Intensive Care Med Date: 2007-04-26 Impact factor: 17.440
Authors: Maurits K Konings; Henk G Goovaerts; Maarten R Roosendaal; Rienk Rienks; Ferry M Koevoets; Ronald L Bleys; Wolfgang F Buhre; Paul M Dorresteijn; Tim Hesselink; Arthur E Officier; Charles L Hollenkamp; Frank E Rademakers Journal: Biomed Eng Online Date: 2012-08-17 Impact factor: 2.819