Literature DB >> 11687360

Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses.

U Gunenc1, F H Oner, S Tongal, M Ferliel.   

Abstract

PURPOSE: To study the effects on visual function of glistenings and folding marks in AcrySof (Alcon) intraocular lenses (IOLs).
SETTING: Department of Ophthalmology, Dokuz Eylül University, School of Medicine, Izmir, Turkey.
METHODS: This study included 91 eyes that had phacoemulsification and in-the-bag AcrySof IOL implantation. Slitlamp, visual acuity, and contrast sensitivity evaluations were used to assess all cases. Observations of folding marks and glistenings in the IOL optic were noted. The glistenings were graded from 0 to +4. Eyes with coexisting pathology that could affect visual acuity (n = 15) were excluded from the study. After the exclusion, the visual acuity and contrast sensitivity in 28 eyes with glistenings were compared with those in 48 eyes without glistenings.
RESULTS: Localized folding marks away from the central visual axis of the IOL were identified in 25 eyes (27.4%). Glistenings were observed in 34 eyes (37.1%), 6 of which were excluded for coexisting pathology. There was no statistically significant difference in visual acuity and contrast sensitivity at low or medium spatial frequencies between eyes with glistenings and those without (P >.05); however, a statistically significant difference was noted at the high spatial frequency (P <.01). There was no difference in visual acuity or contrast sensitivity between eyes with folding marks and those without (P >.05).
CONCLUSION: Although glistenings and folding marks were observed after the implantation of AcrySof IOLs, they did not significantly affect visual function.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11687360     DOI: 10.1016/s0886-3350(01)00995-6

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  16 in total

1.  Effects of glistenings in intraocular lenses.

Authors:  Marrie van der Mooren; Luuk Franssen; Patricia Piers
Journal:  Biomed Opt Express       Date:  2013-07-11       Impact factor: 3.732

2.  Decreased visual function due to high-level light scattering in a hydrophobic acrylic intraocular lens.

Authors:  Shinichiro Yoshida; Hiroyuki Matsushima; Mayumi Nagata; Tadashi Senoo; Ichiro Ota; Kensaku Miyake
Journal:  Jpn J Ophthalmol       Date:  2011-02-18       Impact factor: 2.447

3.  Analysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance.

Authors:  Lei Xi; Yi Liu; Feng Zhao; Chuan Chen; Bing Cheng
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

4.  Light scattering in intraocular lenses explanted 15 to 40 years after surgery.

Authors:  Jorge L Alio; Augusto Arias; Francesco D'Oria; Francesca Toto; Jorge Alio Del Barrio; Raul Duarte; Pablo Artal
Journal:  Biomed Opt Express       Date:  2021-05-18       Impact factor: 3.732

5.  Evolution of visual performance in 70 eyes implanted with the Tecnis(®) ZMB00 multifocal intraocular lens.

Authors:  Carlos Palomino Bautista; David Carmona González; Alfredo Castillo Gómez
Journal:  Clin Ophthalmol       Date:  2012-03-21

6.  Glistenings in hydrophobic acrylic intraocular lenses do affect visual function.

Authors:  George Hh Beiko; Andrzej Grzybowski
Journal:  Clin Ophthalmol       Date:  2013-11-27

7.  Reversible opacification of hydrophobic acrylic intraocular lens- two cases report.

Authors:  Dong Ju Kim; Roy S Chuck; Jimmy K Lee; Choul Yong Park
Journal:  BMC Ophthalmol       Date:  2017-06-30       Impact factor: 2.209

Review 8.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

9.  Prospective multicenter clinical trial to evaluate the safety and effectiveness of a new glistening-free one-piece acrylic toric intraocular lens.

Authors:  Mark Packer; Jon I Williams; Gregg Feinerman; Richard S Hope
Journal:  Clin Ophthalmol       Date:  2018-06-01

10.  Safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (enVista®) - results of a European and Asian-Pacific study.

Authors:  Peter Heiner; Edoardo Ligabue; Alex Fan; Dennis Lam
Journal:  Clin Ophthalmol       Date:  2014-03-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.