Literature DB >> 11685343

Aspiration of dead space allows isocapnic low tidal volume ventilation in acute lung injury. Relationships to gas exchange and mechanics.

E De Robertis1, G Servillo, R Tufano, B Jonson.   

Abstract

OBJECTIVE: In acute lung injury (ALI) mechanical ventilation damages lungs. We hypothesised that aspiration and replacement of dead space during expiration (ASPIDS) allows normocapnic ventilation at higher end-expiratory pressure (PEEP) and reduced tidal volume (V(T)), peak and plateau pressures (Paw(peak), Paw(plat)), thus avoiding lung damage.
SETTING: University Hospital. PATIENTS: Seven consecutive sedated and paralysed ALI patients were studied. INTERVENTIONS AND MEASUREMENTS: Single breath test for CO(2) and multiple elastic pressure volume (Pel/V) curves recorded from different end-expiratory pressures guided ventilatory setting at ASPIDS. ASPIDS was studied at respiratory rate (RR) of 14 min(-1) and then 20 min(-1) with minute ventilation maintaining stable CO(2) elimination.
RESULTS: Alveolar and airway dead spaces were 24.3% and 31.3% of V(T), respectively. Multiple Pel/V curves showed a shift towards lower volume at decreasing PEEP, thus indicating that patients required a higher PEEP. At ASPIDS, PEEP was increased from 8.9 cmH(2)O to 12.6 cmH(2)O and VT reduced from 11 ml/kg to 8.9 ml/kg at RR 14 min(-1) and to 6.9 ml/kg at RR 20 min(-1). A significant decrease in Paw(peak) (36.7 vs 32 at RR 14 min(-1) and 28.7 at RR 20 min(-1)) and Paw(plat) (29.9 vs 27.3 at RR 14 min-1 and 24.1 at RR 20 min-1) were observed. PaCO(2) remained stable. No intrinsic PEEP developed. No side effects were noticed.
CONCLUSIONS: ASPIDS allowed the use of higher PEEP at lower V(T) and inflation pressure and constant PaCO(2). Multiple Pel/V curves gave insight into the tendency of lungs to collapse.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11685343     DOI: 10.1007/s001340101046

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  11 in total

1.  Dynamic elastic pressure-volume loops in healthy pigs recorded with inspiratory and expiratory sinusoidal flow modulation. Relationship to static pressure-volume loops.

Authors:  Ulrika Bitzén; Björn Drefeldt; Lisbet Niklason; Björn Jonson
Journal:  Intensive Care Med       Date:  2004-02-13       Impact factor: 17.440

2.  Elastic pressure-volume curves in acute lung injury and acute respiratory distress syndrome.

Authors:  Björn Jonson
Journal:  Intensive Care Med       Date:  2004-12-17       Impact factor: 17.440

3.  Dead space reduction by Kolobow's endotracheal tube does not justify the waiving of volume monitoring in small, ventilated lungs.

Authors:  Hans Proquitté; Rena Wendel; Charles C Roehr; Roland R Wauer; Gerd Schmalisch
Journal:  J Clin Monit Comput       Date:  2014-01-28       Impact factor: 2.502

4.  Re-inspiration of CO(2) from ventilator circuit: effects of circuit flushing and aspiration of dead space up to high respiratory rate.

Authors:  Edoardo De Robertis; Leif Uttman; Björn Jonson
Journal:  Crit Care       Date:  2010-04-26       Impact factor: 9.097

5.  Heat and moisture exchangers and heated humidifiers in acute lung injury/acute respiratory distress syndrome patients. Effects on respiratory mechanics and gas exchange.

Authors:  Indalecio Morán; Judith Bellapart; Alessandra Vari; Jordi Mancebo
Journal:  Intensive Care Med       Date:  2006-02-24       Impact factor: 17.440

6.  The effect of a pediatric heat and moisture exchanger on dead space in healthy pediatric anesthesia.

Authors:  Min A Kwon
Journal:  Korean J Anesthesiol       Date:  2012-05-24

7.  Computer simulation allows goal-oriented mechanical ventilation in acute respiratory distress syndrome.

Authors:  Leif Uttman; Helena Ogren; Lisbet Niklason; Björn Drefeldt; Björn Jonson
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

8.  Dead space and CO₂ elimination related to pattern of inspiratory gas delivery in ARDS patients.

Authors:  Jerome Aboab; Lisbet Niklason; Leif Uttman; Laurent Brochard; Björn Jonson
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

9.  End-inspiratory pause prolongation in acute respiratory distress syndrome patients: effects on gas exchange and mechanics.

Authors:  Hernan Aguirre-Bermeo; Indalecio Morán; Maurizio Bottiroli; Stefano Italiano; Francisco José Parrilla; Eugenia Plazolles; Ferran Roche-Campo; Jordi Mancebo
Journal:  Ann Intensive Care       Date:  2016-08-24       Impact factor: 6.925

10.  Heat and moisture exchanger filter in a paediatric patient: A dilemma for anaesthesiologists- to use or not to use?

Authors:  Naaz Shagufta; Sinha Chandni; Kumar Ajeet; Asghar Adil
Journal:  Indian J Anaesth       Date:  2020-11-01