Literature DB >> 11681481

Experience of Norwegian general dental practitioners with solid state and storage phosphor detectors.

A Wenzel1, A Møystad.   

Abstract

OBJECTIVES: To evaluate the opinions of Norwegian dental practitioners regarding the use of solid state sensor and storage phosphor (SP) detectors for intra-oral radiography.
METHODS: A questionnaire received from 2199 dentists 309 (219 male, 86 female, four unknown) confirmed the use of digital radiography in their practices.
RESULTS: Sixty-one per cent of dentists used a SP and 35% a sensor system; four (1.3%) used both. Approximately 50% of dentists had experienced technical problems and 33% had needed repairs. Almost all dentists stored their images on the hard disk (>97%) and 81% made a daily back-up. More sensor than SP users found difficulty with the positioning holder. Two-thirds of dentists reported digital image quality was the same or better than film. More Digora (Soredex, Helsinki, Finland) users reported better image quality than Denoptix (Gendex, Milan, Italy) or Digident (Digident, Nesher, Israel) users. Mean reduction in exposure time was 55% (range 2-90%), although 17 dentists stated that no reduction was achieved. Approximately half of the sensor users also used film and 38% of the SP users. Film was used more often for bitewing examination by the sensor users (27%) than by the SP users (4%). Mean time saved by the sensor users was 36 min/day (range 10-120) and by the SP users 25 min/day (range 5-120).
CONCLUSIONS: The majority of dentists felt that digital image quality was the same or better than film and exposure and examination times were reduced. However, technical problems and repairs were common.

Entities:  

Mesh:

Year:  2001        PMID: 11681481     DOI: 10.1038/sj.dmfr.4600613

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  8 in total

1.  Dental students' knowledge and attitudes towards cone beam computed tomography in Turkey.

Authors:  K Kamburoglu; S Kursun; Z Z Akarslan
Journal:  Dentomaxillofac Radiol       Date:  2011-10       Impact factor: 2.419

2.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

3.  The quality of radiographs accompanying endodontic referrals to a health authority clinic.

Authors:  B S Chong; J Miller; S Sidhu
Journal:  Br Dent J       Date:  2015-07-24       Impact factor: 1.626

4.  Digital dental radiology in Belgium: a nationwide survey.

Authors:  Robin Snel; Ellen Van De Maele; Constantinus Politis; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

5.  Effect of explaining radiographic information to the patient before third molar surgery.

Authors:  J Christensen; L H Matzen; A Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2010-03       Impact factor: 2.419

6.  Different digital imaging techniques in dental practice.

Authors:  Amela Lacević; Edina Vranić
Journal:  Bosn J Basic Med Sci       Date:  2004-05       Impact factor: 3.363

7.  Comparison of Swedish and Norwegian Use of Cone-Beam Computed Tomography: a Questionnaire Study.

Authors:  Jerker Edén Strindberg; Caroline Hol; Gerald Torgersen; Anne Møystad; Mats Nilsson; Karin Näsström; Kristina Hellén-Halme
Journal:  J Oral Maxillofac Res       Date:  2015-12-31

8.  Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study.

Authors:  Mohd Yusmiaidil Putera Mohd Yusof; Nur Liyana Abdul Rahman; Amiza Aqiela Ahmad Asri; Noor Ilyani Othman; Ilham Wan Mokhtar
Journal:  Imaging Sci Dent       Date:  2017-12-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.