Literature DB >> 11681476

Generating multiply charged protein ions by ultrasonic nebulization/multiple channel-electrospray ionization mass spectrometry.

J Shiea1, D Y Chang, C H Lin, S J Jiang.   

Abstract

An ultrasonic nebulization/multiple channel electrospray ionization (USN/MC-ES) source, which generates multiply charged peptides and proteins ions, was developed. The source is an ultrasonic nebulizer that is connected to a multiple channel electrospray ionization source. Aerosols were formed by ultrasonically nebulizing the sample solution. The aerosols were then purged into the central channel of a seven-channel ES source via nitrogen gas. A methanol solution that contained 1% trifluroacetic acid was electrosprayed through the outlying six electrosprayers. Detection of multiply charged peptide and protein ions indicated that electrospray was generated from the charged droplet containing analyte. The sample aerosol appeared to fuse with the charged methanol droplet in the air. Then electrospray ionization of the analyte occurred from the newly formed droplet. The peptide and protein prepared in deionized water were detected by this USN/MC-ES-MS. By varying the electrospray solvents, the signals of certain components in the mixture were selectively suppressed.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11681476     DOI: 10.1021/ac0101609

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  9 in total

1.  Electrospray post-ionization mass spectrometry of electrosurgical aerosols.

Authors:  Sabine Guenther; Karl-Christian Schäfer; Júlia Balog; Júlia Dénes; Tamás Majoros; Katalin Albrecht; Miklós Tóth; Bernhard Spengler; Zoltán Takáts
Journal:  J Am Soc Mass Spectrom       Date:  2011-09-03       Impact factor: 3.109

2.  Ultrasonication-assisted spray ionization mass spectrometry for the analysis of biomolecules in solution.

Authors:  Tsung-Yi Chen; Jia-Yi Lin; Jen-Yi Chen; Yu-Chie Chen
Journal:  J Am Soc Mass Spectrom       Date:  2010-05-06       Impact factor: 3.109

3.  Calibrant delivery for mass spectrometry.

Authors:  Bradley B Schneider; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2007-03-23       Impact factor: 3.109

4.  Electrospray Modifications for Advancing Mass Spectrometric Analysis.

Authors:  Anil Kumar Meher; Yu-Chie Chen
Journal:  Mass Spectrom (Tokyo)       Date:  2017-03-24

5.  Extractive Atmospheric Pressure Photoionization (EAPPI) Mass Spectrometry: Rapid Analysis of Chemicals in Complex Matrices.

Authors:  Chengyuan Liu; Jiuzhong Yang; Jian Wang; Yonghua Hu; Wan Zhao; Zhongyue Zhou; Fei Qi; Yang Pan
Journal:  J Am Soc Mass Spectrom       Date:  2016-07-26       Impact factor: 3.109

6.  Analytical performance of a venturi-assisted array of micromachined ultrasonic electrosprays coupled to ion trap mass spectrometry for the analysis of peptides and proteins.

Authors:  Christina Y Hampton; Thomas P Forbes; Mark J Varady; J Mark Meacham; Andrei G Fedorov; F Levent Degertekin; Facundo M Fernández
Journal:  Anal Chem       Date:  2007-10-03       Impact factor: 6.986

7.  Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization.

Authors:  Chong Li; Kushani Attanayake; Stephen J Valentine; Peng Li
Journal:  Anal Chem       Date:  2020-01-15       Impact factor: 6.986

8.  Theta-glass capillaries in electrospray ionization: rapid mixing and short droplet lifetimes.

Authors:  Daniel N Mortensen; Evan R Williams
Journal:  Anal Chem       Date:  2014-09-05       Impact factor: 6.986

9.  Scale-up of microdroplet reactions by heated ultrasonic nebulization.

Authors:  Chengyuan Liu; Jia Li; Hao Chen; Richard N Zare
Journal:  Chem Sci       Date:  2019-08-19       Impact factor: 9.825

  9 in total