Literature DB >> 31940176

Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization.

Chong Li1, Kushani Attanayake1, Stephen J Valentine1, Peng Li1.   

Abstract

Electrospray ionization (ESI) is often affected by corona discharge when spraying 100% aqueous solutions as the voltage that induces discharge can be well below the onset voltage of ESI. As a result, it is especially challenging to perform native mass spectrometry in negative ion mode where 100% aqueous solution is preferred. Here we report a simple instrumentation method to improve the performance of ESI in negative ion mode based on capillary vibrating sharp-edge spray ionization. By attaching a fused silica capillary emitter to a vibrating glass slide, improved signal quality is achieved for various analytes in aqueous solutions over applying ESI alone. Compared to commercial ESI sources using nebulization gas to reduce discharge, 10-100-fold enhancement in signal intensity and 3-10-fold improvement in S/N are achieved for various kinds of molecules including DNA, peptides, proteins, and oligosaccharides. Finally, the new method demonstrates utility for native mass spectrometry analysis of proteins and G-quadruplex DNA. The present method is expected to have great potential to be adopted by the scientific community because of its improved analytical performance, simplicity, and low cost.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31940176      PMCID: PMC7318871          DOI: 10.1021/acs.analchem.9b03983

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  55 in total

1.  A comparison of the electrochemical stabilities of metal, polymer and graphite coated nanospray emitters.

Authors:  Magnus Wetterhall; Oliver Klett; Karin E Markides; Leif Nyholm; Jonas Bergquist
Journal:  Analyst       Date:  2003-06       Impact factor: 4.616

2.  Folded emitters for nanoelectrospray ionization mass spectrometry.

Authors:  Andrea E Kirby; Mais J Jebrail; Hao Yang; Aaron R Wheeler
Journal:  Rapid Commun Mass Spectrom       Date:  2010-12-15       Impact factor: 2.419

3.  Electrospray: from ions in solution to ions in the gas phase, what we know now.

Authors:  Paul Kebarle; Udo H Verkerk
Journal:  Mass Spectrom Rev       Date:  2009 Nov-Dec       Impact factor: 10.946

4.  Compositional protein analysis of high density lipoproteins in hypercholesterolemia by shotgun LC-MS/MS and probabilistic peptide scoring.

Authors:  Manfred Heller; Evelyn Schlappritzi; Daniel Stalder; Jean-Marc Nuoffer; André Haeberli
Journal:  Mol Cell Proteomics       Date:  2007-03-05       Impact factor: 5.911

5.  Negative ion electrospray mass spectrometry of nucleotides: ionization from water solution with SF6 discharge suppression.

Authors:  F M Wampler; A T Blades; P Kebarle
Journal:  J Am Soc Mass Spectrom       Date:  1993-04       Impact factor: 3.109

6.  Ion trap tandem mass spectrometry applied to small multiply charged oligonucleotides with a modified base.

Authors:  S A McLuckey; S Habibi-Goudarzi
Journal:  J Am Soc Mass Spectrom       Date:  1994-08       Impact factor: 3.109

7.  Native electrospray mass spectrometry of DNA G-quadruplexes in potassium solution.

Authors:  Adrien Marchand; Valerie Gabelica
Journal:  J Am Soc Mass Spectrom       Date:  2014-04-30       Impact factor: 3.109

8.  Improvement of shotgun proteomics in the negative mode by carbamylation of peptides and ultraviolet photodissociation mass spectrometry.

Authors:  Sylvester M Greer; Joe R Cannon; Jennifer S Brodbelt
Journal:  Anal Chem       Date:  2014-12-05       Impact factor: 6.986

9.  Compaction of Duplex Nucleic Acids upon Native Electrospray Mass Spectrometry.

Authors:  Massimiliano Porrini; Frédéric Rosu; Clémence Rabin; Leonardo Darré; Hansel Gómez; Modesto Orozco; Valérie Gabelica
Journal:  ACS Cent Sci       Date:  2017-04-26       Impact factor: 14.553

10.  Native electrospray mass spectrometry approaches to probe the interaction between zinc and an anti-angiogenic peptide from histidine-rich glycoprotein.

Authors:  Esther M Martin; Frances D L Kondrat; Alan J Stewart; James H Scrivens; Peter J Sadler; Claudia A Blindauer
Journal:  Sci Rep       Date:  2018-06-05       Impact factor: 4.379

View more
  9 in total

1.  Oxidation Promotes Distinct Huntingtin Aggregates in the Presence and Absence of Membranes.

Authors:  Adewale Adegbuyiro; Alyssa R Stonebraker; Faezeh Sedighi; Caleb K Fan; Breanna Hodges; Peng Li; Stephen J Valentine; Justin Legleiter
Journal:  Biochemistry       Date:  2022-06-27       Impact factor: 3.321

2.  Nanoflow Sheath Voltage-Free Interfacing of Capillary Electrophoresis and Mass Spectrometry for the Detection of Small Molecules.

Authors:  Yousef S Elshamy; Timothy G Strein; Lisa A Holland; Chong Li; Anthony DeBastiani; Stephen J Valentine; Peng Li; John A Lucas; Tyler A Shaffer
Journal:  Anal Chem       Date:  2022-08-01       Impact factor: 8.008

3.  Development of cVSSI-APCI for the Improvement of Ion Suppression and Matrix Effects in Complex Mixtures.

Authors:  Madison E Pursell; Daud Sharif; Anthony DeBastiani; Chong Li; Sandra Majuta; Peng Li; Stephen J Valentine
Journal:  Anal Chem       Date:  2022-06-21       Impact factor: 8.008

4.  Rapid and flexible online desalting using Nafion-coated melamine sponge for mass spectrometry analysis.

Authors:  Chong Li; Amanda DeVor; Jing Wang; Stephen J Valentine; Peng Li
Journal:  Rapid Commun Mass Spectrom       Date:  2022-09-15       Impact factor: 2.586

5.  The Key Role of Metal Adducts in the Differentiation of Phosphopeptide from Sulfopeptide Sequences by High-Resolution Mass Spectrometry.

Authors:  Susy Piovesana; Anna Laura Capriotti; Chiara Cavaliere; Andrea Cerrato; Carmela Maria Montone; Riccardo Zenezini Chiozzi; Aldo Laganà
Journal:  Anal Chem       Date:  2022-06-17       Impact factor: 8.008

6.  Physicochemical Property Correlations with Ionization Efficiency in Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI).

Authors:  Kinkini Udara Jayasundara; Chong Li; Anthony DeBastiani; Daud Sharif; Peng Li; Stephen J Valentine
Journal:  J Am Soc Mass Spectrom       Date:  2020-08-28       Impact factor: 3.109

7.  Combining Field-Enabled Capillary Vibrating Sharp-Edge Spray Ionization with Microflow Liquid Chromatography and Mass Spectrometry to Enhance 'Omics Analyses.

Authors:  Sandra N Majuta; Anthony DeBastiani; Peng Li; Stephen J Valentine
Journal:  J Am Soc Mass Spectrom       Date:  2021-01-08       Impact factor: 3.109

8.  A Small Footprint and Robust Interface for Solid Phase Microextraction and Mass Spectrometry Based on Vibrating Sharp-Edge Spray Ionization.

Authors:  Jing Wang; Chong Li; Peng Li
Journal:  J Am Soc Mass Spectrom       Date:  2022-01-18       Impact factor: 3.262

9.  Characterizing Multidevice Capillary Vibrating Sharp-Edge Spray Ionization for In-Droplet Hydrogen/Deuterium Exchange to Enhance Compound Identification.

Authors:  Anthony DeBastiani; Sandra N Majuta; Daud Sharif; Kushani Attanayake; Chong Li; Peng Li; Stephen J Valentine
Journal:  ACS Omega       Date:  2021-07-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.