Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetes.

M J Tierney1, J A Tamada, R O Potts, L Jovanovic, S Garg.   

Abstract

A device providing frequent, automatic, and non-invasive glucose measurements for persons with diabetes has been developed: the GlucoWatch biographer. This device extracts glucose through intact skin via reverse iontophoresis where it is detected by an amperometric biosensor. The biographer can provide glucose readings every 20 min for 12 h. The performance of this device was evaluated in two large clinical studies in a controlled clinical environment (n=231), and the home environment (n=124). Accuracy of the biographer was evaluated by comparing the automatic biographer readings to serial finger-stick blood glucose (BG) measurements. Biographer performance was comparable in both environments. Mean difference between biographer and finger-stick measurements was -0.01 and 0.26 mmol l(-1) for the clinical and home environments, respectively. The mean absolute value of the relative difference was 1.06 and 1.18 mmol l(-1) for the same studies. Correlation coefficient (r) between biographer and finger-stick measurements was 0.85 and 0.80 for the two studies. In both studies, over 94% of the biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low BG levels. Biographer accuracy is relatively constant over all rates of BG changes, except when BG decreases more than 10 mmol l(-1) h(-1), which occurred for only 0.2% of points in the home environment study. Biographer precision, as measured by CV%, is approx. 10%. Skin irritation, characterized by erythema and edema, was either non-existent or mild in >90% of subjects and resolved in virtually all subjects without treatment in several days.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11679237     DOI: 10.1016/s0956-5663(01)00189-0

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  50 in total

1.  Electroosmosis in transdermal iontophoresis: implications for noninvasive and calibration-free glucose monitoring.

Authors:  Anke Sieg; Richard H Guy; M Begoña Delgado-Charro
Journal:  Biophys J       Date:  2004-08-31       Impact factor: 4.033

Review 2.  Technologies for continuous glucose monitoring: current problems and future promises.

Authors:  Santhisagar Vaddiraju; Diane J Burgess; Ioannis Tomazos; Faquir C Jain; Fotios Papadimitrakopoulos
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

3.  Simultaneous extraction of urea and glucose by reverse iontophoresis in vivo.

Authors:  Anke Sieg; Richard H Guy; M Begoña Delgado-Charro
Journal:  Pharm Res       Date:  2004-10       Impact factor: 4.200

Review 4.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

5.  Detection of trace glucose on the surface of a semipermeable membrane using a fluorescently labeled glucose-binding protein: a promising approach to noninvasive glucose monitoring.

Authors:  Xudong Ge; Govind Rao; Yordan Kostov; Sunsanee Kanjananimmanont; Rose M Viscardi; Hyung Woo; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

Review 6.  Biomedical Perspective of Electrochemical Nanobiosensor.

Authors:  Priti Singh; Shailendra Kumar Pandey; Jyoti Singh; Sameer Srivastava; Sadhana Sachan; Sunil Kumar Singh
Journal:  Nanomicro Lett       Date:  2015-12-21

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

8.  Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring.

Authors:  Tai-Ping Sun; Hsiu-Li Shieh; Congo Tak-Shing Ching; Yan-Dong Yao; Su-Hua Huang; Chia-Ming Liu; Wei-Hao Liu; Chung-Yuan Chen
Journal:  Int J Nanomedicine       Date:  2010-05-13

9.  Microneedle-based automated therapy for diabetes mellitus.

Authors:  Puneet Khanna; Joel A Strom; John I Malone; Shekhar Bhansali
Journal:  J Diabetes Sci Technol       Date:  2008-11

10.  Electrochemical sensor array for glucose monitoring fabricated by rapid immobilization of active glucose oxidase within photochemically polymerized hydrogels.

Authors:  Amos Mugweru; Becky L Clark; Michael V Pishko
Journal:  J Diabetes Sci Technol       Date:  2007-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.