Recording of the fast oscillations in the human electro-oculogram.

F Mergaerts1, E Daems, L Van Malderen, W Spileers.   

Abstract

The fast oscillations (FO) of the electro-oculogram were recorded in 102 eyes of 51 normal subjects. We evaluated the normal range and variability of FO parameters, i.e. Rf, which is the average ratio in percentage of the average amplitude in the dark period (AD) and the average amplitude in the light period (AL), and df, which is the average difference between AD and AL in microV. The standing potential was recorded continuously during six subsequent cycles, each consisting of a one minute period in the dark and one minute period in the light. The mean +/- standard error for Rf was 112.9 +/- 1.3% and 69.6 +/- 5.3 microV for df. There was no statistically significant difference between both genders or different age groups. Rf and df were calculated using a different number of dark-light cycles. In normal subjects both the Rf and df show no difference when only 4 dark-light cycles are used in calculating these values. Therefore there seems no additional advantage in performing as many as 6 cycles. Using 4 dark-light cycles reduces the duration of the examination (8 vs. 12 min) of the fast oscillations and in particular when examining both fast and slow oscillations successively it might be useful to reduce the time of the examination.

Entities:  

Mesh:

Year:  2001        PMID: 11678161     DOI: 10.1023/a:1017915132721

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  14 in total

Review 1.  Clinical electrophysiology of the retinal pigment epithelium.

Authors:  M F Marmor
Journal:  Doc Ophthalmol       Date:  1991       Impact factor: 2.379

Review 2.  Interactions between the retinal pigment epithelium and the neural retina.

Authors:  R H Steinberg
Journal:  Doc Ophthalmol       Date:  1985-10-15       Impact factor: 2.379

3.  Acute blockade of dopamine receptors with haloperidol: a retinal model to study impairments of dopaminergic transmission.

Authors:  G Rudolf; N Wioland
Journal:  Eur J Pharmacol       Date:  1993-01-19       Impact factor: 4.432

4.  Fast oscillations of the electro-oculogram in a series of normal subjects.

Authors:  H Nakao; N Miki; M Nagata; Y Sasaki; A Yamasaki; M Endo; A Setogawa; Y Murata; A Tamai
Journal:  Jpn J Ophthalmol       Date:  1995       Impact factor: 2.447

5.  Standard for clinical electro-oculography. International Society for Clinical Electrophysiology of Vision.

Authors:  M F Marmor; E Zrenner
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

6.  The fast oscillation of the electro-oculogram. Influence of stimulus intensity and adaptation time on amplitude and peak latency.

Authors:  A R Thaler; M R Lessel; P Heilig; V Scheiber
Journal:  Ophthalmic Res       Date:  1982       Impact factor: 2.892

Review 7.  Electro-oculography.

Authors:  H E Kolder
Journal:  Ophthalmologica       Date:  1974       Impact factor: 3.250

8.  Fast and slow oscillations of the electro-oculogram in Best's macular dystrophy and retinitis pigmentosa.

Authors:  R G Weleber
Journal:  Arch Ophthalmol       Date:  1989-04

9.  Calcium blocks selectively the EOG-light peak.

Authors:  H Hofmann; G Niemeyer
Journal:  Doc Ophthalmol       Date:  1985-10-15       Impact factor: 2.379

10.  Is dopamine involved in the generation of the light peak in the intact chicken eye?

Authors:  G Rudolf; N Wioland; I Allart
Journal:  Vision Res       Date:  1991       Impact factor: 1.886

View more
  3 in total

1.  The effects of gender and age on the range of the normal human electro-oculogram.

Authors:  Alisa T Thavikulwat; Patrick Lopez; Rafael C Caruso; Brett G Jeffrey
Journal:  Doc Ophthalmol       Date:  2015-10-16       Impact factor: 2.379

Review 2.  A meta-analysis of clinical electro-oculography values.

Authors:  Paul A Constable; David Ngo; Stephen Quinn; Dorothy A Thompson
Journal:  Doc Ophthalmol       Date:  2017-10-10       Impact factor: 2.379

3.  The fast oscillation of the EOG in diabetes with and without mild retinopathy.

Authors:  Marilyn E Schneck; Leslie Shupenko; Anthony J Adams
Journal:  Doc Ophthalmol       Date:  2007-10-25       Impact factor: 2.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.