Literature DB >> 11641732

Comparison of three-dimensional computed tomography with rapid prototype models in the management of coronoid hyperplasia.

J Asaumi1, N Kawai, Y Honda, H Shigehara, T Wakasa, K Kishi.   

Abstract

OBJECTIVES: To compare (1) the accuracy of 3DCT with rapid prototyping (RP) models and (2) their application in the management of coronoid hyperplasia.
METHODS: An adult dry skull was used to compare 3DCT and a RP model for accuracy of reproduction; Polymerisation contraction and 17 distances between 27 anatomical points were measured. Two patients with coronoid process hyperplasia were assessed by means of 3DCT and plastic models.
RESULTS: Differences in measurements with the RP model and the dried skull were smaller than those with 3DCT (P=0.04). Polymerisation contraction was greater than the errors in reproduction with the RP model and approximately equal to those with the 3DCT. The coronoid process was thick and prominent in the patients with coronoid process hyperplasia and the small space and early contact between zygomatic arch and the coronoid process demonstrated. The plastic model duplicated the exostosis of the inner surface of the malar bone facing the concavity of the elongated process. The coronoid process had an anterior tilt in one case.
CONCLUSION: The plastic model duplicated the relationship between the maxillofacial deformity and the coronoid process with tolerable accuracy. Trismus may be due to the direction as well as the length of the enlarged coronoid process.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11641732     DOI: 10.1038/sj/dmfr/4600646

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  12 in total

1.  Accuracy of medical models made by consumer-grade fused deposition modelling printers.

Authors:  Christian Petropolis; Daniel Kozan; Leif Sigurdson
Journal:  Plast Surg (Oakv)       Date:  2015       Impact factor: 0.947

2.  3D Printing of CT Dataset: Validation of an Open Source and Consumer-Available Workflow.

Authors:  Chandra Bortolotto; Esmeralda Eshja; Caterina Peroni; Matteo A Orlandi; Nicola Bizzotto; Paolo Poggi
Journal:  J Digit Imaging       Date:  2016-02       Impact factor: 4.056

3.  Application of two segmentation protocols during the processing of virtual images in rapid prototyping: ex vivo study with human dry mandibles.

Authors:  Eduardo Gomes Ferraz; Lucio Costa Safira Andrade; Aline Rode dos Santos; Vinicius Rabelo Torregrossa; Izabel Regina Fischer Rubira-Bullen; Viviane Almeida Sarmento
Journal:  Clin Oral Investig       Date:  2013-01-24       Impact factor: 3.573

4.  A digital process for additive manufacturing of occlusal splints: a clinical pilot study.

Authors:  Mika Salmi; Kaija-Stiina Paloheimo; Jukka Tuomi; Tuula Ingman; Antti Mäkitie
Journal:  J R Soc Interface       Date:  2013-04-24       Impact factor: 4.118

5.  Laser direct writing of micro- and nano-scale medical devices.

Authors:  Shaun D Gittard; Roger J Narayan
Journal:  Expert Rev Med Devices       Date:  2010-05       Impact factor: 3.166

6.  Mouth opening limitation caused by coronoid hyperplasia: a report of four cases.

Authors:  Sung-Min Kim; Jin-Hyeok Lee; Hak-Jin Kim; Jong-Ki Huh
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-12-26

7.  An experimental method for stereolithic mandible fabrication and image preparation.

Authors:  Shawn Russett; Paul Major; Jason Carey; Roger Toogood; Pierre Boulanger
Journal:  Open Biomed Eng J       Date:  2007-07-17

8.  The Application of Pre-operative Three-Dimensional Models in the Management of Mandibular Pathology: Is it Really Useful? An Institutional Study.

Authors:  Sanjay Kumar Roy Chowdhury; Arunkumar Shadamarshan Rengasayee; Rajkumar Krishnaprabhu
Journal:  J Maxillofac Oral Surg       Date:  2020-10-16

9.  Dimensional Error in Rapid Prototyping with Open Source Software and Low-cost 3D-printer.

Authors:  Marco A Rendón-Medina; Laura Andrade-Delgado; Jose E Telich-Tarriba; Antonio Fuente-Del-Campo; Carlos A Altamirano-Arcos
Journal:  Plast Reconstr Surg Glob Open       Date:  2018-01-25

10.  Experimental Validation of Plastic Mandible Models Produced by a "Low-Cost" 3-Dimensional Fused Deposition Modeling Printer.

Authors:  Federico Maschio; Mirali Pandya; Raphael Olszewski
Journal:  Med Sci Monit       Date:  2016-03-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.