Literature DB >> 1163894

Intraindividual variability in maximal expiratory flow-volume and closing volume in asymptomatic subjects.

D S McCarthy, D B Craig, R M Cherniack.   

Abstract

The variability of the parameters derived from analysis of the forced vital capacity and the expired nitrogen trace after a vital capacity inhalation of oxygen (closing volume) within a day, from day to day, and from week to week, has been determined. Effort-dependent tests as vital capacity and peak expiratory flow showed the least variability. The greatest variability was seen in effort-independent tests of function such as the maximal expiratory flow rate at 25 per cent (75 per cent of expired vital capacity) and 50 per cent of vital capacity, as well as closing volume. The degree of variability in the tests used was uninfluenced by the periodicity of the tests or the age or smoking habits of the subjects tested. It is suggested that variability of tests of respiratory function should be taken into account in their interpretation.

Entities:  

Mesh:

Year:  1975        PMID: 1163894     DOI: 10.1164/arrd.1975.112.3.407

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  18 in total

1.  Small-airways dysfunction in never smoking asbestos exposed Danish plumbers.

Authors:  M Døssing; S Groth; J Vestbo; O Lyngenbo
Journal:  Int Arch Occup Environ Health       Date:  1990       Impact factor: 3.015

2.  Application of 'flow volume curves' to assess the selectivity of beta-adrenoceptor antagonist drugs.

Authors:  C R Kumana; R Ruffin
Journal:  Br J Clin Pharmacol       Date:  1978-06       Impact factor: 4.335

3.  Intrasubject variability of maximal expiratory flow volume curve.

Authors:  G M Cochrane; F Prieto; T J Clark
Journal:  Thorax       Date:  1977-04       Impact factor: 9.139

4.  Automatisation of the single-breath nitrogen washout test.

Authors:  M F Melo; A Giannella Neto
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

5.  Variable response to inhaled salbutamol of different lung function parameters in healthy children.

Authors:  F Riedel; H von der Hardt
Journal:  Lung       Date:  1986       Impact factor: 2.584

Review 6.  Assessment of changes in airway calibre I. Tests of forced expiration.

Authors:  N B Pride
Journal:  Br J Clin Pharmacol       Date:  1979-09       Impact factor: 4.335

7.  Ventilatory function in the Eisenmenger syndrome.

Authors:  C G MacArthur; D Hunter; G J Gibson
Journal:  Thorax       Date:  1979-06       Impact factor: 9.139

8.  Lung function, maximum and submaximum exercise testing in COPD patients: reproducibility over a long interval.

Authors:  A Noseda; J P Carpiaux; T Prigogine; J Schmerber
Journal:  Lung       Date:  1989       Impact factor: 2.584

9.  Continuous aerosol inhalation scintigraphy in the evaluation of early and advanced airways obstruction.

Authors:  T Weiss; P Dorow; R Felix
Journal:  Eur J Nucl Med       Date:  1984

10.  Diagnostic value of post-bronchodilator pulmonary function testing to distinguish between stable, moderate to severe COPD and asthma.

Authors:  Daphne C Richter; James R Joubert; Haylene Nell; Mace M Schuurmans; Elvis M Irusen
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.