Literature DB >> 11607895

Boneloc bone-cement: experience in hip arthroplasty during a 3-year period.

K F Abdel-Kader1, S Allcock, D I Walker, S B Chaudhry.   

Abstract

Polymethyl methacrylate (PMMA) bone-cement was introduced in the 1960s for fixation of total hip arthroplasty replacement components. Long-term results of cement fixation for hip and knee arthroplasty have been extremely good. Although the use of PMMA bone-cement has enabled long-term survival of joint arthroplasty implants, there has been concern about aseptic loosening. This concern led to the introduction of Boneloc bone-cement (Biomet, Warsaw, IN) in the early 1990s. It was hoped that with the improved physical and chemical characteristics of Boneloc, there would be less aseptic loosening in the long-term. A clinical trial was conducted to evaluate Boneloc bone-cement in cementing the femoral component of the Bimetric total hip arthroplasty prosthesis in 33 hips in 32 patients. On follow-up, 7 stems (24%) developed definite loosening, and 3 stems (10%) were possibly loose. Of the 7 definite loose stems, 5 (17%) were revised because of increasing pain or progressive loosening. Despite the biologic advantages of Boneloc, this study suggests that the chemicals substituted in Boneloc bone-cement led to an alteration in its mechanical properties. These properties proved to be inferior to conventional PMMA bone-cement. There is possible time-dependent deterioration of mechanical properties leading to early aseptic loosening. The conventional PMMA bone-cement has stood the test of time. Research and experimental studies should continue to improve the mechanical properties of Boneloc before further human trials.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11607895     DOI: 10.1054/arth.2001.25561

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Factors affecting the mechanical and viscoelastic properties of acrylic bone cement.

Authors:  A J C Lee; R S M Ling; Sabina Gheduzzi; Jean-Pierre Simon; R J Renfro
Journal:  J Mater Sci Mater Med       Date:  2002-08       Impact factor: 3.896

2.  Editorial Comment: 2016 Knee Society Proceedings.

Authors:  David J Backstein
Journal:  Clin Orthop Relat Res       Date:  2016-09-19       Impact factor: 4.176

Review 3.  Explant analysis and implant registries are both needed to further improve patient safety.

Authors:  M M Morlock; E Gomez-Barrena; D C Wirtz; A Hart; J P Kretzer
Journal:  EFORT Open Rev       Date:  2022-05-31

4.  Creep and fatigue behavior of a novel 2-component paste-like formulation of acrylic bone cements.

Authors:  Ulrike Köster; Raimund Jaeger; Mareike Bardts; Christian Wahnes; Hubert Büchner; Klaus-Dieter Kühn; Sebastian Vogt
Journal:  J Mater Sci Mater Med       Date:  2013-04-06       Impact factor: 3.896

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.