Shielding assessment of a mobile electron accelerator for intraoperative radiotherapy.

J L Daves1, M D Mills.   

Abstract

A new approach to intraoperative radiotherapy makes use of a mobile electron linear accelerator delivering therapeutic radiation doses in an operating room suite. This unconventional technology has raised questions concerning protection for personnel and the necessity of shielding the adjoining areas. In this study, the leakage and scatter radiation from the mobile electron accelerator is measured and characterized in a series of spherical projections. An analysis is performed to determine the need for shielding or, alternatively, patient-based load restrictions in the operating room. This investigation provides a resource to assess shielding and/or patient load restrictions for any facility performing intraoperative radiotherapy with a similar unit. The data presented indicates that the mobile electron accelerator may be operated in an area with little or no shielding under nominal patient load expectations.

Entities:  

Mesh:

Year:  2001        PMID: 11602013      PMCID: PMC5726043          DOI: 10.1120/jacmp.v2i3.2610

Source DB:  PubMed          Journal:  J Appl Clin Med Phys        ISSN: 1526-9914            Impact factor:   2.102


  2 in total

1.  Shielding considerations for an operating room based intraoperative electron radiotherapy unit.

Authors:  M D Mills; P R Almond; A L Boyer; T G Ochran; W Madigan; T A Rich; E B Dally
Journal:  Int J Radiat Oncol Biol Phys       Date:  1990-05       Impact factor: 7.038

2.  The Mobetron: a new concept for IORT.

Authors:  M L Meurk; D A Goer; G Spalek; T Cook
Journal:  Front Radiat Ther Oncol       Date:  1997
  2 in total
  8 in total

1.  Radiation protection for an intra-operative X-ray device.

Authors:  D J Eaton; R Gonzalez; S Duck; M Keshtgar
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

Review 2.  Accelerated Partial Breast Irradiation (APBI): A review of available techniques.

Authors:  Christopher F Njeh; Mark W Saunders; Christian M Langton
Journal:  Radiat Oncol       Date:  2010-10-04       Impact factor: 3.481

Review 3.  Anesthetic Considerations for Intraoperative Radiation Therapy.

Authors:  Kathryn M Glynn; Adam I Riker
Journal:  Ochsner J       Date:  2015

4.  Shielding assessment of a mobile electron accelerator for intra-operative radiotherapy.

Authors:  Alexandre S Krechetov; Donald Goer; Kate Dikeman; Jodi L Daves; Michael D Mills
Journal:  J Appl Clin Med Phys       Date:  2010-09-07       Impact factor: 2.102

5.  Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy.

Authors:  Landon S Wootton; Juergen Meyer; Edward Kim; Mark Phillips
Journal:  J Appl Clin Med Phys       Date:  2017-01       Impact factor: 2.102

6.  Intraoperative radiotherapy using a mobile electron LINAC: a retroperitoneal sarcoma case.

Authors:  A Sam Beddar; Sunil Krishnan
Journal:  J Appl Clin Med Phys       Date:  2005-08-12       Impact factor: 2.102

Review 7.  Present state and issues in IORT Physics.

Authors:  Frank W Hensley
Journal:  Radiat Oncol       Date:  2017-01-27       Impact factor: 3.481

8.  Dose consumption for quality assurance and maintenance at a dedicated IORT accelerator.

Authors:  Frank W Hensley
Journal:  J Appl Clin Med Phys       Date:  2009-10-27       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.