Literature DB >> 11594404

Screening and identification of unknown contaminants in water with liquid chromatography and quadrupole-orthogonal acceleration-time-of-flight tandem mass spectrometry.

I Bobeldijk1, J P Vissers, G Kearney, H Major, J A Van Leerdam.   

Abstract

In order to assess and maintain the quality of surface waters, target compound monitoring is often not sufficient. Many unknown micro-contaminants are present in water, originating in municipal, industrial or agricultural effluents. Some of these might pose a risk to drinking water production and consequently to human health. The possibilities of screening surface water and identification of these non-target water pollutants with modern data acquisition possibilities of hybrid quadrupole-orthogonal acceleration time of flight mass spectrometers (Q-TOF), such as data-dependent MS to MS/MS switching were investigated. Using model compounds, a procedure for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) screening of water extracts was developed, enabling the detection and identification of compounds at levels < or = 0.25 microg/l in surface water. Based on the accurate mass the elemental compositions for the precursor and product ions are calculated. The calculated chemical formulae are searched against the Merck index, the NIST library, an own database containing about 2,500 water pollutants (pesticides and other contaminants) as well as a CI-CID library containing tandem MS spectra of about 100 water contaminants. The developed approach was applied for the identification of unknown compounds, present in native surface water extract. For three of these compounds, structures were proposed. Confirmation of the proposed structures with standards was beyond the scope of this study.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11594404     DOI: 10.1016/s0021-9673(01)01156-6

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Highly-parallel metabolomics approaches using LC-MS for pharmaceutical and environmental analysis.

Authors:  Sunil Bajad; Vladimir Shulaev
Journal:  Trends Analyt Chem       Date:  2007-06-01       Impact factor: 12.296

2.  Determination of aluminium and physicochemical parameters in the palm oil estates water supply at Johor, Malaysia.

Authors:  M R Siti Farizwana; S Mazrura; A Zurahanim Fasha; G Ahmad Rohi
Journal:  J Environ Public Health       Date:  2011-03-07

3.  Neurobehavioral Performance of Estate Residents with Privately-Treated Water Supply.

Authors:  Siti Farizwana Mohd Ridzwan; Zurahanim Fasha Anual; Mazrura Sahani; Ahmad Rohi Ghazali
Journal:  Iran J Public Health       Date:  2013-12       Impact factor: 1.429

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.