Literature DB >> 11590673

Safety and efficacy of suture-mediated closure after percutaneous coronary interventions.

M R Rinder1, P K Tamirisa, M Taniuchi, H I Kurz, K Mumm, J M Lasala.   

Abstract

Percutaneous coronary interventions (PCI) performed with concomitant use of heparin and platelet inhibitors are safe procedures with reported vascular complication rates of approximately 6.1%. EPILOG investigators demonstrated that utilizing a low-dose heparin regimen with abciximab, along with early sheath removal, vascular access-related bleeding was significantly lower than that reported in EPIC. Recently, a suture-mediated closure (SMC) device has been reported to be safe, appears effective, and may improve patient comfort by allowing early ambulation. We conducted a retrospective analysis (January 1999 to March 2000) of complication frequencies among PCI patients who underwent SMC and those who had manual compression (non-SMC). Furthermore, we compared the overall rates of complications to patients who underwent PCI prior to the introduction of SMC (1995-1998). When comparing the current cohort to the historical cohort, there was a significant decrease in the number of retroperitoneal bleeds (0.3% vs. 0.9%; P = 0.003), hematomas (5% vs. 9%; P < 0.001), pseudoaneurysms (1.2% vs. 2.7%; P < 0.001), and need for vascular surgery (0.9% vs. 2.8%; P < 0.001). There was no difference in the number of arterio-venous fistulas and a slight increase in transfusion needs (12% vs. 10%; P = 0.03). Within the current cohort, there was no difference in the vascular complications between SMC and non-SMC PCI patients, although there were lower rates of pseudoaneurysms (0.5% vs. 1.8%; P = 0.02) and transfusion requirements (72/880 vs. 132/874; P < 0.001). These results suggest that the complication rates for SMC are not different and may be lower when compared to non-SMC patients after PCI. At our institution, the practice of early sheath removal and less aggressive heparin dosing has led to a decrease in vascular complication rates and a 66% reduction in vascular surgeries on post-PCI patients. Because of the limitations of retrospective analyses, further studies will be necessary to confirm these findings. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11590673     DOI: 10.1002/ccd.1256

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

Review 1.  Efficacy and safety of the perclose closer s device after neurointerventional procedures: prospective study and literature review.

Authors:  Kamran Khaghany; Firas Al-Ali; Thomas Spigelmoyer; Ron Pimentel; Kurt Wharton
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.