Literature DB >> 11589356

Evaluation of impulse oscillation system: comparison with forced oscillation technique and body plethysmography.

J Hellinckx1, M Cauberghs, K De Boeck, M Demedts.   

Abstract

The impulse oscillation system (IOS) has been developed recently to measure respiratory system resistance (Rrs) and reactance (Xrs) at different frequencies up to > or = 25 Hz. IOS has, however, not been validated against established techniques. This study compared IOS with the classical pseudorandom noise forced oscillation technique (FOT) and body plethysmographic airway resistance (Raw) in 49 subjects with a variety of lung disorders and a wide range of Raw (0.10-1.28 kPa x L(-1) x s). Rrs,IOS was slightly greater than Rrs,FOT, especially at lower frequencies, with a mean +/- SD difference at 5-6 Hz of 0.14 +/- 0.09 kPa x L(-1) x s. Comparisons with the wave-tube technique applied on two analogues indicated an overestimation by IOS. Xrs,IOS and Xrs,FOT were very similar, with a slightly higher resonant frequency with IOS than with FOT (mean difference +/- SD 1.35 +/- 3.40 Hz). Raw was only moderately correlated with Rrn,FOT and Rrs-IOS; although the mean differences were small (0.04 +/- 0.14 kPa x L(-1)s for Rrs6,FOT and -0.10 +/- 0.14 kPa x L(-1) x s for Rrs5,IOS), IOS and FOT markedly underestimated high resistance values. In conclusion, the impulse oscillation system yields respiratory system resistance and reactance values similar, but not identical to those provided by the forced oscillation technique.

Entities:  

Mesh:

Year:  2001        PMID: 11589356     DOI: 10.1183/09031936.01.00046401

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  38 in total

1.  A comparison of lung function methods for assessing dose-response effects of salbutamol.

Authors:  Catherine M Houghton; Ashley A Woodcock; Dave Singh
Journal:  Br J Clin Pharmacol       Date:  2004-08       Impact factor: 4.335

2.  Change in pulmonary function in chronic obstructive pulmonary disease stage 0 patients.

Authors:  Su-Gang Gong; Wen-Lan Yang; Jin-Ming Liu; Wen-Zeng Liu; Wei Zheng
Journal:  Int J Clin Exp Med       Date:  2015-11-15

3.  Medialization of paralyzed vocal fold does not increase respiratory resistance measured by impulse oscillometry.

Authors:  Antti Saarinen; Anssi R A Sovijärvi; Lauri Karhumäki; Heikki Rihkanen
Journal:  Eur Arch Otorhinolaryngol       Date:  2007-07-17       Impact factor: 2.503

4.  Long-Term Pulmonary Function and Quality of Life in Children After Acute Respiratory Distress Syndrome: A Feasibility Investigation.

Authors:  Shan L Ward; Autumn Turpin; Aaron C Spicer; Marsha J Treadwell; Gwynne D Church; Heidi R Flori
Journal:  Pediatr Crit Care Med       Date:  2017-01       Impact factor: 3.624

5.  Comparison of two devices for respiratory impedance measurement using a forced oscillation technique: basic study using phantom models.

Authors:  Kazuya Tanimura; Toyohiro Hirai; Susumu Sato; Koichi Hasegawa; Shigeo Muro; Hajime Kurosawa; Michiaki Mishima
Journal:  J Physiol Sci       Date:  2014-07-18       Impact factor: 2.781

6.  Analysis of anatomical and functional determinants of obstructive sleep apnea.

Authors:  Kensaku Aihara; Toru Oga; Yuka Harada; Yuichi Chihara; Tomohiro Handa; Kiminobu Tanizawa; Kizuku Watanabe; Takefumi Hitomi; Tomomasa Tsuboi; Michiaki Mishima; Kazuo Chin
Journal:  Sleep Breath       Date:  2011-05-15       Impact factor: 2.816

7.  Reproducibility and effect of posture on impulse oscillation parameters in persons with spinal cord injury.

Authors:  Christopher M Cirnigliaro; Marvin Lesser; Jeremy Moyer; Steven C Kirshblum; William A Bauman; Ann M Spungen
Journal:  J Spinal Cord Med       Date:  2012-01       Impact factor: 1.985

8.  Acute effects of hemodialysis on lung function in patients with end-stage renal disease.

Authors:  Susanne M Lang; Anja Becker; Rainald Fischer; Rudolf M Huber; Helmut Schiffl
Journal:  Wien Klin Wochenschr       Date:  2006-03       Impact factor: 1.704

9.  Relationship between peripheral airway function and patient-reported outcomes in COPD: a cross-sectional study.

Authors:  Akane Haruna; Toru Oga; Shigeo Muro; Tadashi Ohara; Susumu Sato; Satoshi Marumo; Daisuke Kinose; Kunihiko Terada; Michiyoshi Nishioka; Emiko Ogawa; Yuma Hoshino; Toyohiro Hirai; Kazuo Chin; Michiaki Mishima
Journal:  BMC Pulm Med       Date:  2010-03-07       Impact factor: 3.317

10.  Evaluation of Inhaled Procaterol for Potential Assist Use in Patients with Stable Chronic Obstructive Pulmonary Disease.

Authors:  Norio Kodaka; Toru Yamagishi; Kayo Watanabe; Kumiko Kishimoto; Chihiro Nakano; Takeshi Oshio; Kumiko Niitsuma; Nagashige Shimada; Hiroto Matsuse
Journal:  Med Princ Pract       Date:  2018-05-17       Impact factor: 1.927

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.