Literature DB >> 11587326

Single-image signal-to-noise ratio estimation.

J T Thong1, K S Sim, J C Phang.   

Abstract

A method for estimating the signal-to-noise ratio from a single image is presented in this paper. The autocorrelation-based technique requires that image details be correlated over distances of a few pixels, while the noise is assumed to be uncorrelated from pixel to pixel. The latter is shown to be a good approximation in the case of scanning electron microscope (SEM) images provided that the video signal is not band limited. The noise component is derived from the difference between the image autocorrelation at zero offset and an estimate of the corresponding noise-free autocorrelation. Nonlinear effects introduced by intensity saturation and their implications on the image signal-to-noise ratio are also discussed.

Year:  2001        PMID: 11587326     DOI: 10.1002/sca.4950230506

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  6 in total

1.  Evaluation of denoising algorithms for biological electron tomography.

Authors:  Rajesh Narasimha; Iman Aganj; Adam E Bennett; Mario J Borgnia; Daniel Zabransky; Guillermo Sapiro; Steven W McLaughlin; Jacqueline L S Milne; Sriram Subramaniam
Journal:  J Struct Biol       Date:  2008-04-22       Impact factor: 2.867

2.  Quantifying melanin spatial distribution using pump-probe microscopy and a 2-D morphological autocorrelation transformation for melanoma diagnosis.

Authors:  Francisco E Robles; Jesse W Wilson; Warren S Warren
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

3.  A cell-level quality control workflow for high-throughput image analysis.

Authors:  Minhua Qiu; Bin Zhou; Frederick Lo; Steven Cook; Jason Chyba; Doug Quackenbush; Jason Matzen; Zhizhong Li; Puiying Annie Mak; Kaisheng Chen; Yingyao Zhou
Journal:  BMC Bioinformatics       Date:  2020-07-02       Impact factor: 3.169

4.  Detection of Particulate Matters with a Field-Portable Microscope Using Side-Illuminated Total Internal Reflection.

Authors:  Haechang Yang; Sanghoon Shin; Dongmin Seo; Jaewon Park; Sungkyu Seo
Journal:  Sensors (Basel)       Date:  2021-04-13       Impact factor: 3.576

5.  Optimization Model of Signal-to-Noise Ratio for a Typical Polarization Multispectral Imaging Remote Sensor.

Authors:  Ying Zhang; Hao Wang; Heshen Li; Junhua Sun; Huilan Liu; Yingshuo Yin
Journal:  Sensors (Basel)       Date:  2022-09-01       Impact factor: 3.847

6.  Psychophysiology of positive and negative emotions, dataset of 1157 cases and 8 biosignals.

Authors:  Maciej Behnke; Mikołaj Buchwald; Adam Bykowski; Szymon Kupiński; Lukasz D Kaczmarek
Journal:  Sci Data       Date:  2022-01-20       Impact factor: 6.444

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.