Literature DB >> 11585294

Clinical role of 99mTcO4/MIBI scan, ultrasound and intra-operative gamma probe in the performance of unilateral and minimally invasive surgery in primary hyperparathyroidism.

D Casara1, D Rubello, M R Pelizzo, B Shapiro.   

Abstract

The main purposes of this study were: (a) to investigate the efficacy of an imaging protocol based on the combination of 99mTcO4/MIBI scintigraphy and neck ultrasound (US) in selecting patients with primary hyperparathyroidism (HPT) for unilateral neck exploration, and (b) to help define the role of the intraoperative MIBI gamma probe (IMGP) technique in the performance of minimally invasive radio-guided surgery (MIRS). One hundred and forty-three consecutive patients with primary HPT were enrolled in the study. We used a modified 99mTcO4/MIBI scintigraphic procedure which included the oral administration of potassium perchlorate to cause rapid 99mTcO4 washout from the thyroid tissue, thereby permitting the acquisition of high-quality early MIBI images. A single-photon emission tomography (SPET) acquisition was also obtained in 21 patients, of whom seven had an enlarged parathyroid gland (EPG) in the mediastinum at planar scintigraphy and 14 had discordant scan/US findings for the presence of a cervical EPG. Neck US was performed in the same session as scintigraphy using a small-parts, high-resolution 10-MHz transducer. All patients were then operated on by the same surgical team. Quick PTH assay (QPTH) was used to measure PTH intraoperatively to confirm successful parathyroidectomy. In patients with scan/US evidence of a solitary EPG and with a normal thyroid gland, limited, unilateral neck surgery or, more recently, MIRS was planned (n=91). In patients with scan/US evidence of multiglandular disease (MGD) (n=21) or concomitant nodular goitre (n=24) or in patients with a negative scan/US evaluation (n=7), extensive bilateral neck exploration was planned (n=52). In 87 of the 91 patients (95.6%) in whom preoperative imaging indicated the presence of a solitary EPG and a normal thyroid gland, a single parathyroid adenoma was found at surgery, and these patients were treated by unilateral neck exploration or MIRS. In the remaining four patients of this group, conversion to bilateral neck exploration was required because parathyroid carcinoma (n=3) or MGD (n=1) was diagnosed at operation. In some cases SPET was helpful in better localising the EPG. In particular, in 5 of the 21 patients evaluated, SPET localised an EPG deep in the neck or mediastinum and at surgery a parathyroid adenoma was found in the paratracheal or para-oesophageal space. In 43 of the 46 patients (93.5%) who were candidates for MIRS, the IMGP technique allowed parathyroidectomy to be performed through a small, 2- to 2.5-cm skin incision with a short duration of intervention (mean 34 min). We conclude that: (a) The integrated scan/US imaging protocol that we used appears to be accurate in selecting patients with primary HPT for unilateral neck exploration. (b) In our series the most prevalent cause of bilateral neck exploration was the co-existence of a nodular goitre; thus accurate preoperative evaluation of the thyroid gland by dual-tracer scintigraphy and US imaging is strongly recommended in all patients with HPT. (c) SPET can provide the surgeon with useful information when an EPG is located deep in the neck or mediastinum. (d) IMGP appears to be a useful intraoperative device in HPT patients with solitary parathyroid adenomas and a normal thyroid gland, since it permits minimally invasive and time-saving surgery.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11585294

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  11 in total

Review 1.  SPECT/CT and tumour imaging.

Authors:  Gad Abikhzer; Zohar Keidar
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-08-29       Impact factor: 9.236

2.  Minimally invasive parathyroidectomy without using intraoperative parathyroid hormone monitoring or gamma probe.

Authors:  Aykut Soyder; Mustafa Ünübol; İmran Kurt Ömürlü; Engin Güney; Serdar Özbaş
Journal:  Ulus Cerrahi Derg       Date:  2015-03-01

3.  Preoperative localization strategies for primary hyperparathyroidism: an economic analysis.

Authors:  Carrie C Lubitz; Antonia E Stephen; Richard A Hodin; Pari Pandharipande
Journal:  Ann Surg Oncol       Date:  2012-07-24       Impact factor: 5.344

4.  Effective factors on the sensitivity of preoperative sestamibi scanning for primary hyperparathyroidism.

Authors:  Nilufar Khorasani; Afshin Mohammadi
Journal:  Int J Clin Exp Med       Date:  2014-09-15

5.  140 consecutive cases of minimally invasive, radio-guided parathyroidectomy: lessons learned and long-term results.

Authors:  M Shabtai; M Ben-Haim; Y Muntz; I Vered; D Rosin; J Kuriansky; O Zmora; D Olchovski; A Ayalon; S T Zwas
Journal:  Surg Endosc       Date:  2003-03-07       Impact factor: 4.584

Review 6.  A comprehensive overview of radioguided surgery using gamma detection probe technology.

Authors:  Stephen P Povoski; Ryan L Neff; Cathy M Mojzisik; David M O'Malley; George H Hinkle; Nathan C Hall; Douglas A Murrey; Michael V Knopp; Edward W Martin
Journal:  World J Surg Oncol       Date:  2009-01-27       Impact factor: 2.754

7.  [Primary hyperparathyroidism: parathyroid scintigraphy and ultrasound in problem patients].

Authors:  E Van De Flierdt; A Dropmann; J Böck; F Spelsberg; H Fürst
Journal:  Chirurg       Date:  2004-08       Impact factor: 0.955

8.  Could the eZ-SCOPE AN gamma camera replace intraoperative measurement of iPTH for PHPT?

Authors:  Takaaki Fujii; Reina Yajima; Satoru Yamaguchi; Soichi Tsutsumi; Takayuki Asao; Hiroyuki Kuwano
Journal:  Int Surg       Date:  2012 Apr-Jun

9.  Scintigraphic techniques in primary hyperparathyroidism: from pre-operative localisation to intra-operative imaging.

Authors:  Domenico Rubello; Milton D Gross; Giuliano Mariani; Adil AL-Nahhas
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-10       Impact factor: 10.057

10.  Role of cervical ultrasonography in primary hyperparathyroidism.

Authors:  Feroze Shaheen; Nisar Chowdry; Tariq Gojwari; Arshad Iqbal Wani; Showkat Khan
Journal:  Indian J Radiol Imaging       Date:  2008-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.